Reliability Specification (Tbc); Reliability Compliance; Reliability Prediction Model; Life Stress Test - Sierra Wireless AirPrime HL77 Series Product Technical Specification

Table of Contents

Advertisement

6. Reliability Specification (TBC)

AirPrime HL77xx modules will be tested against the Sierra Wireless Industrial Reliability Specification
defined below.
6.1.

Reliability Compliance

AirPrime HL77xx modules connected on a development kit board application are targeted to be
compliant with the following requirements.
Table 38.
Standards Conformity
Abbreviation
Definition
IEC
International Electro technical Commission
ISO
International Organization for Standardization
6.2.

Reliability Prediction Model

6.2.1.

Life Stress Test

The following tests the AirPrime HL77xx modules' product performance.
Table 39.
Life Stress Test
Designation
Performance Test
PT3T & PTRT
41110555
Condition
Standard: N/A
Special conditions:
Temperature:
Class A: -30°C to +70°C
Class B: -40°C to +85°C
Rate of temperature change: ± 3°C/min
Recovery time: 3 hours
Operating conditions: Powered
Duration: 14 days
Rev 1.0