Product Technical Specification
6.2.6.
Handling Resistance Stress Tests
The following tests the AirPrime HL77xx modules' resistance to handling malfunctions and damage.
Table 44.
Handling Resistance Stress Tests
Designation
ESDC Test
ESD Test
Free Fall Test
FFT 1
41110555
Condition
Standard: JESD22-A114, JESD22-A115, JESD22-C101
Special conditions:
HBM (Human Body Model): 1KV (Class 1C)
•
MM (Machine Model): 200V
•
CDM (Charged Device Model): 250V (Class II)
•
Operating conditions: Powered
Duration: 3 days
Standard: IEC 61000-4-2
Special conditions:
Contact Voltage: ±2kV, ±4kV, ±6kV
•
Air Voltage: ±2kV, ±4kV, ±8kV
•
Operating conditions: Powered
Duration: 3 days
Standard: IEC 60068-2-32, Test Ed
Special conditions:
Number of drops: 2 drops per unit
•
Height: 1m
•
Operating conditions: Un-powered
Duration: 6 hours
Rev 1.0
Reliability Specification (TBC)
November 01, 2017
48