4.4

Scan Festo Devices

This scan program finds all controllers connected to the network.
1.
Click the icon in the toolbar of the CODESYS program window or
click the menu command [Online] [Scan Festo Devices].
Figure: "Scan Festo Devices" scan program
2.
Click the button to select the controller "CECC-X".
3.
Click the "Scan for" button to start a new scan.
All found devices are listed in the scan program table.
4.4.1

Changing network properties:

1.
Click the found device.
2.
Open the "Network properties" dialog:
menu command [Actions] [Device] [Network Properties] or
context menu [Network Properties].
Figure: "Network properties" dialog
3.
Change the IP address if it is already assigned in the network.
4.
Adapt the settings for the subnet mask, standard gateway and DNS server to your network
environment.
5.
Apply the changes to the device. To do this, click "OK".
6.
Wait until the device has successfully completed the switch-on process ("RUN" status LED lights up).
7.
Close the "Scan Festo Devices" scan program.
Festo controller CECC-X-M1-...
13