Result display

Overview

To display the trace only select Trace in the Trace/Table softkey.
1
2
Fig. 11
Example of result display (Trace only)
1. Filename (only if file was stored)
2. Mini-trace
3. Number of acquisition
4. File settings:
The displayed parameters depend on the settings in the File
settings menu. Following parameters may be displayed:
[Fiber Id] [Fiber Number] [Cable Id]
5. Trace results associated with cursors A and B:
A, B: Wavelengths and power at point of trace referenced by
cursors A and B
A-B: Wavelength and power difference between cursors A and B
6. Alarm result (see
7. Trace/Table selection
8. Channel number
9. Trace with markers
10. Table of results (see