Troubleshooting Based on Alarm Codes
E65: Thermostat Open
E65
High Vent restriction, High-Limit Thermostat defective or Inlet Thermal Limiter
tripped.
Checks to perform:
Check the ventilation of Dryer. Is the ventilation clean?
(See Fig. 1)
Check Inlet Thermal Limiter for the continuity. Is the
continuity there?
Check the working of Exhaust Vent System (there
should not be any air blockage) (See Fig. 2)
Check High-Limit Thermostat for the continuity. Is the
continuity there?
Replace the Electronic Control Board and repeat the
diagnostic cycle to check for any further alarms.
Y
E
S
Y
E
S
Y
E
S
Y
E
S
WARNING
Check that all the connectors are correctly
inserted.
Clean the ventilation and repeat the diagnostic
NO
cycle to check for any further alarms.
Replace Inlet Thermal Limiter and repeat the
NO
diagnostic cycle to check for any further alarms.
Remove the air blockage and make Exhaust Vent
System proper and repeat the diagnostic cycle to
NO
check for any further alarms.
Replace High-Limit Thermostat and repeat the
NO
diagnostic cycle to check for any further alarms.
50
E65