Troubleshooting Based on Alarm Codes
E94: Cycle Configuration Checksum
E94
Wrong configuration data loaded or Electronic control Board defective.
Checks to perform:
Check if correct Cycle Selector Board, User Interface Board and Electronic Control Board are installed. If not
then replace the respective board and repeat the diagnostic cycle to check for any further alarms. Incorrect
E97: Missing Program on CTF
E97
Discrepancy between programme configuration data and selector recognition data.
Checks to perform:
Check if correct Cycle Selector Board, User Interface Board and Electronic Control Board are installed. If not
then replace the respective board and repeat the diagnostic cycle to check for any further alarms. Incorrect
E9C: User Interface Configuration Checksum
E9C
Software problem between Main Board and Control Board.
Checks to perform:
Check if correct User Interface Board and Electronic Control Board are installed. If not then replace the
respective board and repeat the diagnostic cycle to check for any further alarms.
E9E: User Interface Touch Sensor Not Working
E9E
Humidity or water on User Interface Board or User Interface Board defective.
Checks to perform:
Switch OFF the Dryer and check for water or humidity on User Interface Board, dry it and switch it ON again
then check whether problem is solved or not. If not then replace the User Interface Board and repeat the
Error
configuration possible.
Error
configuration possible.
diagnostic cycle to check for any further alarms.
WARNING
Check that all the connectors are correctly
inserted.
WARNING
Check that all the connectors are correctly
inserted.
Error
WARNING
Check that all the connectors are correctly
inserted.
WARNING
Check that all the connectors are correctly
inserted.
54
E94
E97
E9C
E9E