2.6.2 Ignition Control Wiring
To activate ignition control, you need to provide IGN signal via the 3-pin
pluggable terminal block located in the back panel. It is below the general wiring
configuration.
Pin No.
Definition
1
Ignition (IGN)
2
External Power S/W +
3
External Power S/W +
For testing purpose, you can refer to the picture blow to simulate ignition signal
input controlled by a latching switch.
Note:
1. DC power source and IGN share the same ground.
2. IVH-9200 supports 6V~36V wide range DC power input in ATX/AT mode. In
Ignition mode, the input voltage is fixed to 12V/24V for car battery scenario.
3. For proper ignition control, the power button setting should be "Power down"
mode.
V+
IGN
In Windows, for
example, you need
to set "When I press
the power button" to
"Shut down."