6
Setting Up Triggers

Setting up a Trigger on Physical Layer Errors

Physical Layer Errors Supported for Triggering

The U4301 Analyzer supports the following physical layer error types to allow you to set up a trigger
on error.
Physical Layer Error
Symbol Error
(Applicable for Gen1 and Gen2 speeds)
Disparity Error
(Applicable for Gen1 and Gen2 speeds)
Block Header Error
(Applicable only for Gen3 speed)
Idle Symbol Error
(Applicable for Gen1, Gen2, and Gen3
speeds)

To set up a trigger on error

For a simple trigger
1
2
3
66
Occurrence of Trigger on Error
On encountering an invalid symbol
On encountering an incorrect disparity
On encountering an error in Sync bits (start of block)
On encountering data other than Idle symbol during logical idle on an active lane.
In the Trigger dialog box, select the Simple Trigger radio button.
From the list of trigger events displayed in the left-side pane, expand the Physical Layer Triggers
events category.
Drag and drop the Physical Layer Error(s) event from the left-side to the Select the Trigger(s) to use
section on the right. By using this event, you set up trigger on all the supported physical layer
errors (described in the table above).