8.5.4

Zone 2 with type of protection Ex nA IIC Gc, non sparking

Low-voltage motors
Operating Instructions, 05/2014, 5 610 00000 02 000
II
3
2
CE - or EAC marking
Code for prevention of explosions
Device group: II not for mining, but other hazardous zones
Device category: 3 for infrequent, short-term danger
Atmosphere: G for gas
Explosion protection: International
Type of protection: "nA" for non-sparking
Explosion group: IIC for acetylene
Temperature Class: T3 for maximum surface temperature of 200° C
Device protection level: Gc for an extended level of protection in hazardous zones with
explosive gas mixtures
Identification number or name of nominated testing agency
Zone 2
"X" special conditions
G
Ex
Ex
nA
nA
IIC
IIC
T3
Operation
8.5 Class
T3
Gc
Gc
X
83