1. Open the red locking lever
2. Release the snap hook on the compartment and remove the jumper
3. Press the jumper
4. Press the jumper
Explosion-protected machines (with the exception of machines for Zone 22) are equipped
with terminal boxes with type of protection increased safety "e".
For 1MJ machines, terminal boxes with type of protection flameproof enclosure "d" with
explosion group IIC are available as an option.
Please note in this regard design, connection options and spare parts.
Note the explosion protection information designated with
Have authorized Siemens workshops perform any repairs.
6.1.8.3

Protruding connection cables

Risk of short-circuit and voltage hazard
A short-circuit can occur if the connecting cables are clamped between the enclosure parts
and cover plate. This can result in death, severe injury and material damage.
During disassembly and particularly when installing the cover plate, make sure that the
connecting cables are not clamped between enclosure parts and the cover plate.
Low-voltage motors
Operating Instructions, 05/2014, 5 610 00000 02 000
fully into the base of the slot and engage the locking lever at its end
position.
into the compartment and allow the snap hooks to re-engage at the
compartment.
WARNING
and remove the jumper
Electrical connection
6.1 Connecting the machine
from the slot.
.
in the operating instructions!