Operation
8.4 Deactivating
8.4
Deactivating
Commission any devices provided for protection against condensation after switching off the
machine.
8.5
Class
8.5.1
Zone 1 with type of protection Ex de IIC Gb (flameproof enclosure "d" for the
machine and increased safety "e" for the terminal box)
158
①
②
③
①
②
①
②
③
④
⑤
⑥
⑦
⑧
⑨
⑩
⑪
⑫
⑬
⑭
80
II
2
④
⑤
1
Ex
③
⑬
⑦
CE - or EAC marking
Identification number or name of nominated testing agency
Code for prevention of explosions
Device group: II not for mining, but other hazardous zones
Device category: 2 for occasional danger and for use in Zone 1
Atmosphere: G for gas
Explosion protection: International
Type of protection: "d" Flameproof Enclosure of machine
Type of protection: "e" Increased Safety of terminal box
Explosion group: IIC for acetylene
Temperature class: T4 for maximum surface temperature of 135° C
Device protection level: Gb for a high level of protection in hazardous zones with
explosive gas mixtures
Zone 1
"X" special conditions
G
Ex
d
⑥
⑦
⑧
d
e
⑧
⑨
Operating Instructions, 05/2014, 5 610 00000 02 000
e
IIC
T4
⑨
⑩
⑪
IIC
T4
Gb
⑩
⑪
⑫
Low-voltage motors
Gb
⑫
X
⑭