Do not use this dust collector for other than its function. Check for alignment of moving parts, intended use. If used for other purposes, JET binding of moving parts, breakage of parts, disclaims any real or implied warranty and holds...
Whatever accepted methods are used, always make personal safety a priority. If there are questions or comments about this product, please contact your local supplier or JET. JET can also be reached at our web site: www.jettools.com.
12.0 Warranty and service ..........................15 The specifications in this manual were current at time of publication, but because of our policy of continuous improvement, JET reserves the right to change specifications at any time and without prior notice, without incurring obligations.
4.0 Specifications Table 1 Model number DC-500P Stock number 717500 Motor and electrical Motor type totally enclosed fan cooled, induction, capacitor start Horsepower 3/4HP (0.55 kW) Phase 1 PH Voltage 115/230 V Cycle 60 Hz Listed FLA (full load amps) 7.5/3.75 A...
Read and understand the entire contents of this manual before attempting assembly or operation. Failure to comply may cause serious injury. 5.0 Setup and assembly 5.1 Unpacking Remove all contents from shipping carton and compare to the contents list in this manual. If shipping damage or any part shortages are identified, contact your distributor.
5.4 Assembly Install casters (G, Figure 5-3), to base, using the fasteners supplied with each caster, in the order as shown. Tighten the hex nut and cap nut to secure. A caster can be locked in position by pushing down on the adjoining lever. Push up lever to unlock caster.
3 hole locations. The center hole must be centered The DC-500P Dust Collector is rated at 115/230V on a wall stud, and should be approximately 40 power, and is pre-wired for 115 volt. The unit comes inches from floor –...
7.0 Operation 8.0 User-maintenance 7.1 Switch key Turn OFF dust collector and remove plug from power source before To prevent accidental or unauthorized use, turn performing adjustments or maintenance. Failure machine off and remove safety key (Figure 7-1). to comply may result in serious injury. Store key in a safe place, inaccessible to children.
9.0 Troubleshooting DC-500P Dust Collector Symptom Possible Cause Correction* Motor will not start. No incoming current. Check connections at plug or circuit panel. Safety key missing from switch. Install safety key. Low voltage. Check power line for proper voltage. Open circuit in motor or loose Inspect all connections to switch box and connection.
Non-proprietary parts, such as fasteners, can be found at local hardware stores, or may be ordered from JET. Some parts are shown for reference only, and may not be available individually. 10.1.1 DC-500P Portable Dust Collector – Exploded View...
JET sells through distributors only. The specifications listed in JET printed materials and on official JET website are given as general information and are not binding. JET reserves the right to effect at any time, without prior notice, those alterations to parts, fittings, and accessory equipment which they may deem necessary for any reason ®...