Annex 1 : Example Of A Dumped File - GDD Instrumentation MPP-EM2S Plus Instruction Manual

Mpp probe
Hide thumbs Also See for MPP-EM2S Plus:
Table of Contents

Advertisement

Annex 1 : Example of a Dumped File

Num
Date
STAMP:
0.00
m
2
29-01-09
3
29-01-09
4
29-01-09
5
29-01-09
6
29-01-09
7
29-01-09
8
29-01-09
9
29-01-09
10
29-01-09
11
29-01-09
12
29-01-09
13
29-01-09
14
29-01-09
STAMP:
0.50
m
16
29-01-09
17
29-01-09
18
29-01-09
19
29-01-09
20
29-01-09
21
29-01-09
22
29-01-09
23
29-01-09
STAMP:
1.00
m
25
29-01-09
26
29-01-09
27
29-01-09
28
29-01-09
29
29-01-09
30
29-01-09
31
29-01-09
m
STAMP:
1.50
With the default settings, the readings are equally distributed between two stamped marks (the REPARTITION
box in the MEMORY page of the MPP Program is checked) in the continuous mode. That is why it is important
to move the probe with a constant speed along the core sample. If you unchecked the REPARTITION box, the
word AUTO will appear instead of the position. In manual mode, checking Repartition box will cause erroneous
positions.
In this dumped file, the ? symbol (SYM) means that the probe cannot measure the magnetic susceptibility and
the conductivity accurately. This problem occurs when the values are too low (around zero).
Instrumentation GDD Inc.
Hour
Position
U
10:39:42
0.00
m
10:39:44
0.04
m
10:39:46
0.08
m
10:39:48
0.12
m
10:39:51
0.15
m
10:40:19
0.19
m
10:40:21
0.23
m
10:40:23
0.27
m
10:40:25
0.31
m
10:40:27
0.35
m
10:40:29
0.38
m
10:40:31
0.42
m
10:40:33
0.46
m
10:40:36
0.50
m
10:40:38
0.56
m
10:40:40
0.63
m
10:40:42
0.69
m
10:40:44
0.75
m
10:40:46
0.81
m
10:40:48
0.88
m
10:40:50
0.94
m
10:40:52
1.00
m
10:40:54
1.07
m
10:40:56
1.14
m
10:40:58
1.21
m
10:41:00
1.29
m
10:41:02
1.36
m
10:41:04
1.43
m
2018-01-16
Diameter
Half
SYM
25.4
No
25.4
No
25.4
No
25.4
No
25.4
No
25.4
No
25.4
No
25.4
No
25.4
No
25.4
No
25.4
No
25.4
No
25.4
No
25.4
No
25.4
No
25.4
No
25.4
No
25.4
No
25.4
No
25.4
No
25.4
No
25.4
No
25.4
No
25.4
No
25.4
No
25.4
No
25.4
No
25.4
No
HF_Resp
SYM
Scpt
30
27.9
0
?
0.3
0
?
0.4
0
?
0.5
0
0.6
6
7.4
50
91.3
11
38.3
2
12.6
2
6.5
1
3.1
2
7.7
1
9.3
2
9.5
1
8.6
1
5.5
1
6.0
2
9.0
1
7.0
2
11.1
1
3.7
1
3.9
1
4.0
26
43.2
11
23.6
5
15.6
4
15.0
5
16.4
SYM
Cond
38.1
?
0.0
?
0.0
?
0.0
?
0.0
783
577
666
?
0.0
?
0.0
?
0.0
?
0.0
?
0.0
?
0.0
?
0.0
?
0.0
?
0.0
?
0.0
?
0.0
?
0.0
?
0.0
?
0.0
?
0.0
612
1553
7347
9351
5647
67

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MPP-EM2S Plus and is the answer not in the manual?

Related Products for GDD Instrumentation MPP-EM2S Plus

Table of Contents