3.3 REMOTE
CONTROL
 
The remote control works via infra red and can be used to operate the LHS from long distances. 
It operates using 2 x AAA batteries and these can be exchanged by unclipping a cover on the rear 
of the remote control unit. 
3.5  USER
PARAMETERS 
 
Five USER parameters are on the SHS, to access these power up the scale and whilst the display 
is counting down press and then release the [Unit] button. The display will show 00000. Use the 
[Hold] and [Unit] buttons to enter the code 11111 and then press [Zero]. bEE 1 will be displayed. 
Press  the  [Hold]  button  to  change  the  setting  and  the  [Zero]  button  to  move  to  the  next 
parameter.  
 
PARAMETER SETTING TABLE 
FUNCTION 
EE 
B
H
 
OD
S
 
TB
CH
 
T
YES 
 
© Adam Equipment Company 2017
UNIT 
 
DESCRIPTION 
Sets buzzer 
0: Disable    1: Enable   
Sets the Hold function 
0: Peak   1: Standard   
Sets the Stable function 
0: Disable   1: Enable   
Sets weighing unit on power up 
0: kg   1: Lb's 
2:  Newtons(Newtons  not  available  for  "a" 
models) 
Sets save: 
0:  Not saved  1:  Save new settings 
 
 
DEFAULT
8