Advertisement

(P.N. 9596, Revision D, July 2014)
© Adam Equipment Company 2014
LBK SERIES
Adam Equipment
99 Washington Street
Melrose, MA 02176
Phone 781-665-1400
Toll Free 1-800-517-8431
Visit us at www.TestEquipmentDepot.com

Advertisement

Table of Contents
loading

Summary of Contents for Adam Equipment LBK Series

  • Page 1 Adam Equipment LBK SERIES (P.N. 9596, Revision D, July 2014) 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 © Adam Equipment Company 2014 Visit us at www.TestEquipmentDepot.com...
  • Page 2 © Adam Equipment Company 2014...
  • Page 3 Easy Reference: Model name of the scale: Serial number of the unit: Software revision number (Displayed when power is first turned on): Date of Purchase: Name of the supplier and place: © Adam Equipment Company 2014...
  • Page 4 © Adam Equipment Company 2014...
  • Page 5: Table Of Contents

    6.4 PARTS COUNTING FUNCTION ..............12 6.5 PERCENTAGE WEIGHING FUNCTION ............12 6.6 USER CALIBRATION FUNCTION ..............12 6.7 SELECTION OF WEIGHING UNITS ..............13 7.0 CALIBRATION ....................14 7.1 AUTOMATIC EXTERNAL CALIBRATION ............14 8.0 ERROR MESSAGE ..................15 © Adam Equipment Company 2014...
  • Page 6 © Adam Equipment Company 2014...
  • Page 7: Introduction

    • Indicators for Stable, zero, net weight, and low battery functions • Stainless steel pan with ABS case and pan support • Sealed Membrane keypad • Overload Protection • Spirit level and leveling feet • Auto calibration, zero tracking and tare © Adam Equipment Company 2014...
  • Page 8: Specifications

    10kg/20kg/30kg or Weights 2lb/4lb/6lb 4lb/8lb/12lb 10lb/20lb/25lb 20lb/40lb/60lb Display 6digit LCD display, green backlight Net wt. 1.8kg/4lb LBK-a models are supplied to North and South American markets only and are available from Adam Equipment USA office. © Adam Equipment Company 2014...
  • Page 9: Safety Precautions

    • Put the pan support in place, inserting the pan support pins into the holes on top of the scale. Place the stainless steel pan on the support. © Adam Equipment Company 2014...
  • Page 10: Assembling Of Battery And Power

    Internal rechargeable batteries (where used) can be changed, but please first ask for technical support from your dealer or the manufacturer. Replacement batteries should be type BT-6M4.0AC(6V4AH) or equivalent. Please dispose of and recycle used batteries carefully and according to local laws and regulations. © Adam Equipment Company 2014...
  • Page 11: Weighing

    • If a container is used, put the container on the pan and press [Tare] key when the reading is stable. The display will show “0.00” and the zero symbol and net weight symbol. © Adam Equipment Company 2014...
  • Page 12: Pound/Ounce Mode

    • Press [Zero] key once the stability indicator comes on to confirm the entered value. The display will show the number of pieces placed on the pan. • If more items are put on the pan, the increased count value will be shown. © Adam Equipment Company 2014...
  • Page 13: Percentage Weighing

    • When another item with a different weight value is put on the pan, the relative % value would be shown against the initial reference sample value. • Press [Func] key to exit and go back to weighing mode. 5.4.3 CALIBRATION • Refer to section 7 for details © Adam Equipment Company 2014...
  • Page 14: Function Setting

    • “On bL”: backlight will be on all the time. • Press [Unit] to confirm and move to the next setting. • When you enter the unit setting mode, it will show “On PEr” or “OFF PEr”. © Adam Equipment Company 2014...
  • Page 15: Parts Counting Function

    [Func] key to overleap this function and move to the next setting. • Press [Unit] key to confirm the setting and enter the next setting. It g " or "OFF g". enters unit setting when it shows "On © Adam Equipment Company 2014...
  • Page 16: Selection Of Weighing Units

    Auto Off. To leave the Function Settings section, turn the scale off and on again to enter the normal weighing mode and save the changes make. © Adam Equipment Company 2014...
  • Page 17: Calibration

    • The display will now show the calibration mass expected. ”CAL XX Kg “ or ”CAL XX Lb “ .Press [Tare] key to change the calibration values if necessary. Each model has 3 different kg and lb calibration selection values. © Adam Equipment Company 2014...
  • Page 18: Error Message

    L) or too high (FAIL H) in respect to the previous calibration value. 8.0 ERROR MESSAGE ---ADO A/D counts are too high ---ADL A/D counts are too low --ERR- Wrong operation Unit-E All the units are disabled Low battery indication © Adam Equipment Company 2014...
  • Page 19 State of California to cause cancer and birth defects or other reproductive harm. Adam Equipment products have been tested with, and are always supplied with mains power adaptors which meet all legal requirements for the intended country or region of operation, including electrical safety, interference and energy efficiency.
  • Page 20 No part of this publication may be reprinted or translated in any form or by any means without the prior permission of Adam Equipment. Adam Equipment reserves the right to make changes to the technology, features, specifications and design of the equipment without notice.