8. Push the control knob in all the way and hold it in. Immediately push the piezo ignition button (the
black button second from the left) repeatedly so that it clicks; continue until the pilot ignites. Maintain
pressure on the knob for about one minute after ignition. Then release the knob; if the pilot flame goes
out repeat step 8; if the pilot flame remains on then turn the knob counter-clockwise to the "ON"
position.
9. If the pilot lights, but will not stay on after several tries, turn the gas control knob to the "OFF" position
and call your service technician or gas supplier. If the control knob does not pop out when released,
- shut off the gas supply to the control valve, and
S
TOP
supplier.
10. If equipped with a wall switch, select the "ON" position. If equipped with a thermostat or auxiliary
control, set it to the desired setting.
11. Close the access door by lifting it, allowing the springs to pull it closed.
f i r e - p a r t s . c o m
Shutdown Procedure
1. To turn off the main burner only, turn off the wall switch, thermostat, or the On/Off switch located on
the lower right side behind the access door.
2. For complete shutdown of the appliance, depress the gas control knob and turn it clockwise to the
position.
2.3 H
O
A
EAT
UTPUT
DJUSTMENT
I
MMEDIATELY
Figure 3
call your service technician or gas
"O
"
FF
/9