Transport And Interim Storage; Intended Use - salmson SUBSON Premium 20 MFP Installation And Operating Instructions Manual

Hide thumbs Also See for SUBSON Premium 20 MFP:
Table of Contents

Advertisement

Available languages

Available languages

ENGLISH
1. GENERAL
About this document
These installation and operating instructions are an integral
part of the product. They must be kept readily available at the
place where the product is installed. Strict adherence to these
instructions is a precondition for the proper use and correct
operation of the product.
These installation and operating instructions correspond to the
relevant version of the product and the underlying safety
standards valid at the time of going to print.
2. SAFETY
These operating instructions contain basic information which
must be adhered to during installation and operation. For this
reason, these operating instructions must, without fail, be read
by the service technician and the responsible operator before
installation and commissioning.
It is not only the general safety instructions listed under the main
point "safety" that must be adhered to but also the special
safety instructions with danger symbols included under the fol-
lowing main points.
2.1 Indication of instructions in the operating instructions
Symbols:
General danger symbol
Danger due to electrical voltage
USEFUL INFORMATION
Signal words:
DANGER!
Acutely dangerous situation
Non-observance results in death or the most serious of
injuries.
WARNING!
The user can suffer (serious) injuries. 'Warning' implies
that (serious) injury to persons is probable if this infor-
mation is disregarded.
CAUTION!
There is a risk of damaging to the pump/installation.
'Caution' implies that damage to the product is likely if
the information is disregarded.
NOTE: Useful information on using the product. It draws
attention to possible problems.
2.2 Personnel qualifications
The installation personnel must have the appropriate qualifica-
tions for this work.
2.3 Danger in the event of non-observance of the safety
instructions
Non-observance of the safety instructions can result in risk of
injury to persons and damage to pump/installation. Non-
observance of the safety instructions can result in the loss of
any claims for damages.
In detail, non-observance can, for example, result in the follow-
ing risks:
•Failure of important functions of the pump/installation,
•Failure of specified maintenance and repair procedures,
•Risks to persons through electrical, mechanical and bacterio-
logical effects,
•Property damage.
2.4 Safety instructions for the operator
The existing directives for accident prevention must be
adhered to. Danger from electrical current must be elimi-
nated. Local directives or general directives [e.g. IEC, VDE
etc.] and local power supply companies must be adhered to.
Risks through mechanical or bacteriological effects must be
prevented. Local conditions and guidelines relating to sewage
technology must be adhered to.
2.5 Safety instructions for inspection and installation work
The operator must ensure that all inspection and installation
work is carried out by authorised and qualified personnel, who
are sufficiently informed from their own detailed study of the
operating instructions.
Work to the pump/installation must only be carried out when at
a standstill.
2.6 Unauthorised modification and manufacture of spare
parts
Modifications to the pump/installation are only permissible
after consultation with the manufacturer. Original spare parts
and accessories authorised by the manufacturer ensure
safety. The use of other parts can nullify the liability from the
results of their usage.
2.7 Improper use
The operational safety of the supplied pump/unit is only guar-
anteed for conventional use in accordance with section 4 of
the installation and operating instructions. The limit values must
on no account fall under or exceed those specified in the cat-
alogue/data sheet.

3. TRANSPORT AND INTERIM STORAGE

As soon as the product arrives:
•Check the product for damage in transit,
•In the case of transport damage, initiate the necessary proce-
dures with the forwarding agent within the time stipulated.
CAUTION! Danger of property damage!
Incorrect transport and incorrect intermediate storage
can lead to product damage.
•The pump may only be suspended/carried by the strap
provided for transport purposes. The cable should
never be used for lifting!
•The pump must be protected against moisture, frost and
mechanical damage when transported and stored.

4. INTENDED USE

The SUBSON Premium series drainage and submersible waste
water pumps are used:
•for the automatic drainage of pits and shafts,
•for keeping dry yard areas and basement rooms exposed to
flooding,
•for lowering surface water,
if the waste water is not able to flow off into the sewer system
through natural fall.
The pumps are suitable for pumping slightly contaminated
water, rainwater, drainage water and washing water.
The pumps are usually installed under water (submerged) and
can only be permanently or transportably installed vertically.
Because of the sheath current cooling, the pumps can also be
operated unsubmerged.
Submersible pumps with a mains connection cable of less than
10 metres are (according to EN 60335) only permitted for use
inside buildings, i.e. not for operating outside.