• Leakages (e.g. from the shaft seals) of hazardous
fluids (which are explosive, toxic or hot) must be led
away so that no danger to persons or to the environ-
ment arises. National statutory provisions are to be
complied with.
• Highly flammable materials are always to be kept at
a safe distance from the product.
• Danger from electrical current must be eliminated.
Local directives or general directives [e.g. IEC, VDE
etc.] and local power supply companies must be
adhered to.
2.6 Safety instructions for installation and mainte-
nance work
The operator must ensure that all installation
and maintenance work is carried out by author-
ised and qualified personnel, who are sufficiently
informed from their own detailed study of the
operating instructions.
Work on the product/unit must only be carried out
when at a standstill. It is mandatory that the pro-
cedure described in the installation and operating
instructions for shutting down the product/unit
be complied with.
Immediately on conclusion of the work, all safety
and protective devices must be put back in posi-
tion and/or recommissioned.
2.7 Unauthorised modification and manufacture of
spare parts
Unauthorised modification and manufacture of
spare parts will impair the safety of the product/
personnel and will make void the manufacturer's
declarations regarding safety.
Modifications to the product are only permissible
after consultation with the manufacturer. Original
spare parts and accessories authorised by the
manufacturer ensure safety. The use of other parts
will absolve us of liability for consequential events.
2.8 Improper use
The operating safety of the supplied product is
only guaranteed for conventional use in accord-
ance with Section 4 of the operating instructions.
The limit values must on no account fall under
or exceed those specified in the catalogue/data
sheet.

3. Transport and interim storage

The system is supplied on a pallet, it is protected
from moisture and dust with a transparent plastic
cover.
• The equipment must be transported by means of
authorised load devices.
ATTENTION! The handling should be done by a
skilled staff and with an authorized equipment.
Transport straps must be secured to the existing
transport lugs or placed round the base frame.
The pipes will not withstand loads and should not
be used to secure loads in transit.
Any load on tanks union is prohibided.
Some stickers on manifolds and tank reminds this
advice (Fig. 1).
SALMSON 04/2014
(Fig. 1) ADVICE STICKER.
ATTENTION! Loading the pipes in transit can
result in leaks.
Any load on the union can result in leaks.
ATTENTION! If the product is installed later on,
store it in a dry place. Protect it from impacts
and any outside influences (moisture, frost, etc.).
Handle the product with care.
4. Applications
The system is designed for pressure keeping in a
close loop of heating or cooling where variation of
temperature exists.
The system ensure also the filling of installation. The
booster is supplied from the public water mains.

5. Product data

5.1 Type key
Example: Expanson Comfort-H305-2-CE-T-2D
Comfort
Standard version with pumps MUH or MUV
Pump model : H = horizontal
H
V = vertical
305
Nominal flow and number of stages
of each pumps (m
3 m
/h: pump MUH 3 or MUV 3
3
2
Mode of system:
1 = 1 pump
2 = 1 pump + safety pump
CE
Type of automatism:
CE = Electronic controller
T
T = Three-phases 400V
M = Single-phase 230V
Number of dischargers:
2D
Nothing = 1 discharger
2D = 2 dischargers
5.2 Technical data
• Max. operating pressure
maintained:
• Max. water temperature:
• Max. ambiant temperature:
• Single-phase voltage:
• Three-phase voltage:
5.3 Scope of delivery
• System without tank (provided separately).
• Control box.
• Installation instructions: booster, pump and
automatism.
• Safety instruction.
5.4 Accessories (compulsory)
• Tank to size with installation data (200L to
5000L available).
Do not handle by this
component.
Do not apply load on
this component.
3
/h):
6 bars for H
8 bars for V
+5 °C to +90 °C
+40 °C
50 Hz 230V
50 Hz 400V
English