Instruction
Recommended service
intervals for APP pumps
(180R9199)
Table of Contents
1.
General information
2.
Design/features
32
Recommended service intervals for APP pumps
1.
General information
2.
Design/features
3.
Appendix 1
This guideline provides information on the
recommended service intervals. The recommen-
dation is based upon good engineering practice
and on experience gained from operation even
under extreme conditions.
Danfoss APP pumps are designed for long
operation and low maintenance and life cycle
costs.
Danfoss guarantees 8,000 hours service free
operation, however max. 18 months from date of
production. After 8,000 operation hours it is
recommended to inspect the pump and replace
worn parts, if any.
Nr.
Qty.
Description
1
1
Housing, main bearing
11, 125,
1
Mounting flange/
211*
end flange
121, 181*
1
Port flange
31
1
Swash plate
66
5/7/9
Piston
92
1
Valve plated
91
1
Port plate
61
1
Cylinder barrel
65
1
Retaining plate
64
1
Retaining ball
71
1
Retaining guide
62
1/4
Spring
63
1
Spring guiede
142
1
Stop for shaft seal
124, 215*
1
Shaft seal
125
1
Cover/flange for
shaft seal
93
5/7/9
Back-up ring
*
O-ring (overall)
*
Screw (overall)
*
Pin (overall)
152
1
Valve cone (flushing valve)
3, 129*
2
Bleeding screw
67
1
Parallel key
*
depends on pump size
180R9265 / IOM APP 16-22 Appendices - v02 / 01.2013
The recommendation is for guidance only.
If the Danfoss recommendations concerning
system-design (see our data sheet) are not
followed, the service life of the APP pumps might
be affected.
The recommended service intervals on the
different parts in the APP pumps appear from the
table below:
Material
Service interval
Duplex, PEEK
No need for service
Wetted part: Duplex
No wear part
Dry part: AISI 316L
Duplex
No wear part
Super Duplex
40,000 hours
Super Duplex and PEEK
Recommended inspection
on a yearly basis and
evaluated acc. to app. 1
Super Duplex
24,000 hours
Super Duplex, PEEK
24,000 hours
Super Duplex
40,000 hours
Super Duplex
24,000 hours
Super Duplex
40,000 hours
Super Duplex
40,000 hours
Duplex
40,000 hours
Duplex or PP
40,000 hours
PP
No wear part
Hasteloy and NBR
It is good practice to
change the seal after each
disassembly of the pump
Super Duplex
No wear part
Teflon
24,000 hours
NBR
24,000 hours
AISI 316
No wear part
AISI 316, Duplex or PEEK
No wear part
Duplex or PEEK
40,000 hours
Duplex
No wear part
AISI 302
40,000 hours
Need help?
Do you have a question about the APP series and is the answer not in the manual?