1.1.1 Material Calibration
The "Material Calibration" menu item allows you to set a material-specific calibration stored
in the probe. In addition, you have the possibility to carry out your own calibrations in order
to be able to measure special materials.
Der Menüpunkt „Materialkalibrierung" ermöglicht es, eine in der Sonde gespeicherte
materialspezifische Kalibrierung einzustellen. Außerdem haben Sie hier die Möglichkeit
eigene Kalibrierungen durchzuführen, um auch spezielle Materialien vermessen zu können.
Note: Pressing the key
key
for a long time, regardless of which material calibration sub-point is currently active,
you return to the probe setting menu.
1.1.1.1
Choose Calibration Curve
The sub-item "Select" allows you to select between up to 15 material-specific calibrations.
1.1.1.2
Change
The "CHANGE" sub-point allows you to perform a 1-point calibration or 2-point calibration.
Manual SONO-VIEW Version 3_1
briefly will take you to the previous menu point. By pressing the
After selecting the menu item "Material cal.", use the
/
buttons to "CHOOSE" one of the 15 stored
material-specific calibrations or "CHANGE" to perform
a new calibration on one of the 15 calibration memories.
The corresponding sub-point is selected with the key
and the key
Use the
specific calibrations. The "!" shows the current standard
calibration
calibration with the button
probe. The setted calibration curve is not stored in the
probe. By pressing the key
item "Select" again.
Use the
calibration and 2-point calibration. The corresponding
procedure is executed with the key
for finishing this procedure.
leaves this menu point.
/
buttons to select between the material-
before
calibration.
, you can leave this sub-
/
buttons to toggle between 1-point
Save
the
selected
as a standard in the
and the key
is
Seite 17