Fcc Compliance Statement; Industry Canada Statement - DSC TL280R Installation Manuals

Internet alarm communicator international
Hide thumbs Also See for TL280R:
Table of Contents

Advertisement

Ethernet Programming Worksheets
Internet Alarm Communicator Installation Guide

FCC Compliance Statement

CAUTION: Changes or modifications not expressly approved
by the Digital Security Controls could void your authority to
use this equipment.
This equipment has been tested and found to comply with the lim-
its for a Class B digital device, pursuant to Part 15 of the FCC
Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. How-
ever, there is no guarantee that interference will not occur in a par-
ticular installation. If this equipment does cause harmful
interference to radio or television reception, which can be deter-
mined by turning the equipment off and on, the user is encouraged
to try to correct the interference by one or more of the following
measures:
- Re-orient the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected.
- Consult the dealer or an experienced radio/television technician
for help.
The user may find the following booklet prepared by the FCC
useful: 'How to Identify and Resolve Radio/Television Interfer-
ence Problems'. This booklet is available from the U.S. Govern-
ment Printing Office, Washington D.C. 20402, Stock # 004-000-
00345-4.

Industry Canada Statement

This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme
NMB-003 du Canada.
EN50131 Compliant installations
1. The TL280R, TL280 module is monitored by the control panel
and it is programmed via the programming menu (* 8, section
[851] in the control panel. The interface is connected to the PC-
Link bus as shown in the diagram included in this manual.
2. The Ethernet port is protected against surge transients up to
2.5kV and it is immune to conducted and radiated RF fields with
levels up to 10V/m as tested per EN50130-4 Standard.
3. The TL280R, TL280 module conforms with radiated emissions
levels for Class B equipment as per standards EN61000-6-3/
EN55022/CISPR22.
4. The TL280R, TL280 module uses AES128 encryption and
heartbeat supervision for both the Ethernet communication path
and it meets security levels S2 as per EN50136-2-1 (EN50131-1).
It also uses authentication for each message exchanged with the
compatible receiver equipment at ARC and it meets level I2 for
information security.
5. The TL280R, TL280 module has only one communication
path: Ethernet 10/100BaseT using Internet/Intranet network.
TL280 and TL280R have been certified by Telefication in accor-
dance with EN50131-1 requirements for Grade 2, Class II and
ATS Class 3,4,5.
12

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tl280

Table of Contents