6 CONTROL PANEL
A = Gas pre flow
B = Slope up
C = Slope down
D = Gas post flow
6.5

MMA settings

Symbol
Function
MMA*
Current
Arc force
Hot start
Remote
control unit*
*) Parameter cannot be changed while welding
6.5.1

Hidden MMA functions

There are hidden functions in the control panel. To access the functions, press parameter
selection button for 3 seconds (see section SETTING PANEL for button placement). The
display shows a letter and a value. Select function by pressing the same button. The knob is
used to change the value of the selected function. To exit hidden functions, press the button
for 3 seconds again.
Letter
Function
C
Arc force
H
Hot start
6.5.2
Measured values
Measured current
Measured value in the display for welding current A is arithmetic average value.
0463 416 001
E = Set current
F = Remote min current
G = Current range adjustable by the foot
pedal
Setting range
Setting steps
ON/OFF
1ph: 5–200 A
3ph: 5–300 A
0–99
0–99%
ON/OFF
- 30 -
Default
ET 300i ET 300iP
value
ON
1
100 A
1
50
1
20%
OFF
H = Hidden
function
Settings
0–99
0–99%
X
X
H
H
H
H
X
X
© ESAB AB 2017