Addressing; Control Board - Future light SC-240 Scanner User Manual

Hide thumbs Also See for SC-240 Scanner:
Table of Contents

Advertisement

4.1.4 Channel 4 - Shutter, Strobe, Gobos
0 - 5
6 - 63
64 - 127
128 - 132
133 - 135
136 - 143
144 - 151
152 - 159
160 - 167
168 - 175
176 - 183
184 - 191
192 - 199
200 - 207
208 - 215
216 - 223
224 - 231
232 - 239
240 - 247
248 - 255
The Control Board on the top side of the SC-240 allows you to assign the DMX fixture address, which is
defined as the first channel from which the SC-240 will respond to the controller.
If you set, for example, the address to channel 5, the SC-240 will use the channel 5 to 8 for control.
Please, be sure that you don't have any overlapping channels in order to control each SC-240 correctly and
independently from any other fixture on the DMX data link.
If two, three or more SC-240 are addressed similarly, they will work similarly.
For address setting follow this procedure:
1. Switch on the SC-240 and wait until the fixture reset has finished ("rES" is flashing at the display).
2. Browse through the menu by pressing the [
"001". Confirm by pressing [
3. Use the [
] and [
4. Confirm by pressing [
Controlling:
After having addressed all SC-240, you may now start operating these via your lighting controller.
Note:
After switching on, the SC-240 will automatically detect whether DMX 512 data is received or not. If there is
no data received at the DMX-input, the display will start to flash "001" with actually set address.
This situation can occur if:
- the 3 PIN XLR plug (cable with DMX signal from controller) is not connected with the input of the SC-240
- the controller is switched off or defective, if the cable or connector is defective or the signal wires are swap
in the input connector.
Note:
It's necessary to insert the XLR termination plug (with 120 Ohm) in the last lighting in the link in order to
ensure proper transmission on the DMX data link.
The Control Board situated on the top side of the SC-240 offers several features. You can simply set the
lighting address, run test shows, make a reset and also use special functions.
Browse through the menu by the pressing [
messages: "001, rPA, rtil, tSt, rES". Press [
are described in the following sections and the function hierarchy is shown below.
Shutter closed
Full open position
Strobe-effect from slow to fast (max. 8 flashes/second)
Closed
Reset of the fixture
Full open position
Closed in reverse position
Gobo 1
Gobo 2
Gobo 3
Gobo 2
Gobo 4
Gobo 5
Gobo 3
Gobo 6
Gobo 7
Gobo 4
Gobo 8
Gobo 9
Gobo 10
Gobo 11
Gobo 12
Gobo 13

5. Addressing

] key and "001" will start to flash frequently.
] keys to select the desired address.
] .

6. Control Board

Gobo 1
Gobo 5
Gobo 6
Gobo 7
] and [
] keys until the display shows current address
] and [
] keys - the display shows step by step these
] if you wish to select one of them. The functions provided
12
Gobo 13
Gobo 12
Gobo 11
Gobo 10
Gobo 9
Gobo 8

Hide quick links: