Page 1
W6010DE/J GENERATOR INSTALLATION AND OPERATORS MANUAL WINCO INC. 225 S. CORDOVA AVE. LE CENTER, MN 56057 SALES DEPT. 507-357-6821 SERVICE DEPT. 507-357-6831 www.wincogen.com...
TABLE OF CONTENTS COPY YOUR MODEL AND SERIAL NUMBER HERE No other WINCO generator has the same serial number as yours. If you should ever need to contact us on this unit, it will help us to SAVE THESE INSTRUCTIONS respond to your needs faster.
SPECIFICATIONS SAFETY GENERATOR IMPORTANT SAFETY INSTRUCTIONS Model W6010DE/I & /J SAVE THESE INSTRUCTIONS Starting Watts 6,010 Running Watts 5,160 This manual contains important information that should be understood Volts 120/240 and followed before the installation, operation and maintenance of the...
INTRODUCTION 3. NOISE HAZARD - INTENDED USES Excessive noise is not only tiring, but continual exposure can lead to loss of hearing. A. Use hearing protection when working around this This engine generator set has been designed primarily for portable equipment for long periods of time.
UNIT CAPABILITIES Self-exciting generators respond to severe overloading differently than utility power. When overloaded, the engine is not able to supply enough GENERATOR CONNECTIONS power to bring the electric motor up to operating speed. The generator responds with high initial starting current, but the engine speed drops sharply.
1. As you receive your unit, it is critical to check it for any damage. If any damage is noted, it is always easiest to refuse the shipment and let WINCO take care of the freight claim. If you sign for the unit, the transfer of the ownership requires that you file the freight claim 2.
BATTERY INSTALLATION 3. Check both the battery cable ends and the battery posts to be sure they are free of corrosion. 4. Always connect the battery positive first and then connect the This engine generator set is shipped with a battery tie down for battery negative cable.
INITIAL START UP LIFTING EYE INSTALLATION The throttle control on these generators is preset and locked to operate at 3600 RPM (nominal) with no load speed set at 3690 RPM. Only a trained service technician should be allowed to adjust this speed setting.
CONNECTING THE LOADS 5. Return key to 1st position when engine is running (Ref A). The engine-generator covered in this manual was designed for portable use. Do NOT operate indoors. The unit should be stored in a warm, dry location. Move the unit outdoors to a flat, dry location for use. WARNING: PERSONAL DANGER: Operating any engine driven generator without proper air flow can result in personal injury or death.
Be sure it can handle the intended load and is The WINCO YourGen meter allows you to see useful information about compatible with the voltage, phase, and current ratings. ‘Hard wiring’...
Operating Speed Output voltage of Line 2 (L2 on panel) to neutral. See the Load vs. Output table for an explanation of voltage and frequency ranges under All engines have a tendency to slow down when a load is applied. load.
ENGINE CARE have not been reached. Certain operating environments may also require more frequent oil changes. MAINTENANCE SCHEDULE Alarms - The display will start blinking and toggle to the first parameter that Daily or Every Every is out of specification. The panel will remain flashing until the fault Every 10 hrs 250* hrs 500** hrs...
C. Replace oil drain plug. B. Remove the wing nut. D. Remove oil fill cap. C. Remove the filter element. E. Fill to correct level with oil. Reinstall cap. F. Remove the oil filter and dispose of it properly. D. Check the rubber seal is undamaged. NOTE: This engine requires 41.6 oz.
GENERATOR CARE TROUBLESHOOTING Problem Possible Causes Proper care and maintenance of the generator is necessary to ensure a Won’t start Low oil level long trouble free life. Out of fuel Start switch in OFF position EXERCISING THE GENERATOR Fuel Valve turned off Plugged fuel filter Blown fuse in key switch The generator should be operated every three to four weeks.
WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE. WINCO is liable for the repair or replacement of the product only and is not liable for incidental or consequential damages as permitted by your state. This warranty gives you specific legal rights which may vary from state to state.
Need help?
Do you have a question about the W6010DE/I and is the answer not in the manual?
Questions and answers