4.6.2
Change battery step-
by-step
4.7
44

Battery for the TS Instrument

1
7
2
6
0016256_001
1.
Face the instrument so that the vertical drive screw is on the left.
The battery compartment is below the vertical drive. Turn the knob to
the vertical position, opening the lid of the battery compartment.
2.
Pull out the battery housing.
3.
Pull the battery out of the battery housing.
4.
At the top of the battery is a notch which corresponds to the inner
surface of the battery housing. This notch helps you to place the
battery correctly.
5.
Place the battery into the battery housing, ensuring that the contacts
are facing outward. Click the battery into position.
6.
Place the battery housing into the battery compartment. Push the
battery housing in until it fits completely into the battery compart-
ment.
7.
Turn the knob to lock the battery compartment. Ensure that the knob
is returned to its original horizontal position.

Working with the Memory Device

Keep the card dry.
Use it only within the specified temperature range.
Do not bend the card.
Protect the card from direct impacts.
Failure to follow these instructions could result in data loss and/or permanent
damage to the card.
The TS13 with the four button keyboard and without display uses the memo-
ries only for firmware/license key upload.