Table 3-4. Air Condensation Temp - NORTHROP GRUMMAN Patara I User Manual

Table of Contents

Advertisement

1%
10%
10
-43.9
-20.2
12
-42.6
-18.7
14
-41.4
-17.1
16
-40.2
-15.6
18
-39.0
-14.1
20
-37.8
-12.5
22
-36.6
-11.0
24
-35.4
-9.5
26
-34.2
-8.0
28
-33.0
-6.5
30
-31.8
-4.9
32
-30.6
-3.4
34
-29.5
-1.9
36
-28.3
-0.4
38
-27.1
1.1
40
-26.0
2.6
© 2018 Cutting Edge Optronics, Inc.

Table 3-4. Air Condensation Temp

at Given Ambient Air Temp (°C) and Relative Humidity (%)
Relative Humidity
20%
30%
-11.9
-6.8
-10.3
-5.0
-8.6
-3.3
-7.0
-1.6
-5.3
0.2
-3.6
1.9
-2.0
3.6
-0.4
5.3
1.3
7.1
2.9
8.8
4.6
10.5
6.2
12.2
7.8
13.9
9.5
15.7
11.1
17.4
12.7
19.1
If required to operate a laser in conditions near to the condensation temperature,
take precautions to keep the laser dry. The laser should be operated inside an area
that is purged with nitrogen (N
40%
50%
60%
-3.0
0.1
2.6
-1.2
1.9
4.5
0.6
3.7
6.4
2.4
5.6
8.2
4.2
7.4
10.1
6.0
9.3
12.0
7.8
11.1
13.9
9.6
12.9
15.7
11.3
14.8
17.6
13.1
16.6
19.5
14.9
18.4
21.4
16.7
20.3
23.2
18.5
22.1
25.1
20.2
23.9
27.0
22.0
25.7
28.9
23.8
27.6
30.7
) or encased in a sealed enclosure with desiccant.
2
18
Chapter 3: System Details
70%
80%
90%
100%
4.8
6.7
8.4
10.0
6.7
8.7
10.4
12.0
8.6
10.6
12.4
14.0
10.5
12.5
14.4
16.0
12.4
14.5
16.3
18.0
14.4
16.4
18.3
20.0
16.3
18.4
20.3
22.0
18.2
20.3
22.3
24.0
20.1
22.3
24.2
26.0
22.0
24.2
26.2
28.0
23.9
26.2
28.2
30.0
25.8
28.1
30.1
32.0
27.7
30.0
32.1
34.0
29.6
32.0
34.1
36.0
31.6
33.9
36.1
38.0
33.5
35.9
38.0
40.0
Patara I and II Laser User Manual