Operational Procedure
Once your lift columns are installed, operation is simple. Using the wired remote will allow full control over
extending and retracting the lift columns. Use the up button to raise the column lifts and the down button to lower
the column lifts.
You can program up to 4 locations using the memory setup: Use the up/down buttons on the remote to find your
desired height(s), then press "S" followed by a number 1-4. The column heights position is now saved. To move to
the set position, hold the number button.
Reset Procedure
IMPORTANT
You must reset the lifting columns prior to use:
If the lifting columns are not functioning properly or the LED screen displays "RST" or "Er1" - "Er13", please
follow the reset procedure: Unplug the power cord and lifting columns for 30 seconds. Plug the lifting columns
into the control box ensuring a secure connection then plug the power cord in before continuing to the next step.
If the columns lifts are raised at all, press and hold the DOWN button on the remote until the lifting columns are
fully retracted. Press and hold the DOWN button for 10 seconds until the LED display reads "ASr". If you are
using a spare remote without an LED, hold the DOWN button for 10 seconds.
Once "ASr" is displayed on the remote, press and hold the down DOWN until the lifting columns lower, slightly
rise, then stop. Release the button and the table lift is now ready to use.

Troubleshooting

If your lifting columns are not functioning it may require a reset. Follow the RESET procedure.
If your hand remote has an LED display and it displays "RST" (reset), perform the reset procedure.
If the LED displays shows an error message ("Er1" - "Er13"), confirm that all wired connections are
secure. Then perform the reset procedure.
If the LED remote displays "HOT", let the unit cool down for 20 minutes.
If the error message persists after the reset procedure, contact us at 1-800-676-6123 or