ORIGINAL AQUAPURE, PURELINK, & CM3 TESTS
A B C D E F G H J K
Test
Points
A to C -- 21 VAC
K to H -- 120 mVDC
Test Point
Common
Cell Current on Front Board
A B C D E F G H J K
Test
Points
A to C -- 21 VAC
K to H -- 120 mVDC
Test Point
Common
Voltage on Front Board
(All test point voltages are marked on the board)
Flow Sensor
21
OFF
ACV
DCV
750
1000
200
200
DCA
200µ
20
2000µ
2
20m
200m
200m
2000K
10A
200K
h
FE
20K
2K
200
W
NPN
PNP
(All test point voltages are marked on the board)
Flow Sensor
120
OFF
ACV
DCV
750
1000
200
200
DCA
200µ
20
2000µ
2
20m
200m
200m
2000K
10A
200K
h
FE
20K
2K
200
W
NPN
PNP
1
RED BLK YEL GRN
R-Temp H-Temp Salinity
Disconnect Flow Sensor Before
Using Test Switches
Salinity – 2.8 GPL
R-Temp – 75 F
H- Temp 91 F
1 2 3 4
RED BLK YEL GRN
R-Temp H-Temp Salinity
Disconnect Flow Sensor Before
Using Test Switches
Salinity – 2.8 GPL
R-Temp – 75 F
H- Temp 91 F
30
Test the voltage from the
back board at test points
2 3 4
A & C.
-If the voltage is not
confirm that the
VAC
( ± 10%)
ribbon cable that
connects the back board
to the front board is not
damaged and that it is
seated correctly and
retest. If the retest
remains outside the
required voltage, perform
a back board test.
Cell Current is tested
through DC Millivolts.
Test the current from the
cell at test points H & K.
-If the voltage is higher
than 160 mVDC or less
than 120 mVDC, confirm
that the ribbon cable that
connects the back board
to the front board is not
damaged and that it is
seated correctly and
retest. If the retest
remains outside the
required voltage, perform
a back board test.
Informational Note:
20 millivolts =
1 ampere on a 1400 unit
40 millivolts =
1 ampere on a 700 unit
21