SERVICE CODE FLOW CHARTS
Does the 170 appear
Code 170
upon power up to the
AquaPure without
waiting for the 5
minute wait period?
Code combination of
170 & 187?
Code combination of
170 & 191?
Code combination of
170 & 193?
Code combination of
170 & 195?
Inspection, Voltage, & Current Tests on pages 17-23.
Yes
Turn Power off, remove the
Sensor from the PIB, and
Power Up the AquaPure.
Does the 170 appear upon
power up without waiting the
5 minute wait period?
No
Inspect Sensor and
replace.
Conduct a transformer voltage test on the PIB.
Are the readings correct.
No
Check incoming Power.
-If the voltage is below 108 VAC when wired for 115 or below 216 VAC when
wired for 230, the voltage is too low for proper operation.
-If the voltage is good, replace the transformer.
Test cell voltage at the cord
connection on the PIB. Is the
voltage less then 19 VDC?
Yes
Visually check the DC cell cord
and outside of cell. Are they
connected loosely together or are
there signs of damage?
Yes
Loose connection = Reconnect
firmly.
Damaged cell or cord = Replace
cell and cord.
Next, Restart the unit and wait for
system diagnostics.
(Approximately 5
minutes).
PIB measured significant
current when the unit is
either resting or off. Replace
PIB.
Yes
Conduct a sensor
reading test. Does it
pass the test?
No
Yes
Perform transformer
voltage test and sensor
reading test. Replace
the PIB or Transformer
as needed.
No
Replace
Yes
PIB.
Are there 160 DC
No
Millivolts or higher at the
cell current test points?
Remove Cell and
No
visually check calcium
build up and or debris. Is
the cell clean?
Yes
Reinstall and restart the unit. Wait for
system diagnostics.
(Approximately 5 minutes).
Does the system show the same
service code?
Yes
Replace the PIB.
Replace the flow sensor.
Replace the PIB.
26
Restart the unit and wait for
No
system diagnostics.
Yes
Check for Metals in the water and
possible shorts between the plates
& posts on the cell and inside the
cord.
No
Clean the cell with 4 parts water and 1
part muriatic acid. Rinse with fresh
water when done.
No Code = System
Operating Normally
No
Different Code = Proceed to
that code.