PROTECTION POLICY REGISTRATION CARD is included. The completed card must be returned to Jandy within 30 days of installation for the Surge Protection Policy to be in effect. Note that this kit contains components to protect a base system only. Depending on how your installation is wired, and the number of options, you may need additional surge boards (order P/N 6585).
Page 3
Power Center can be "doubled up" on the red terminal bar, see Figure 1. CAUTION Never connect more than two wires on each of the pins of the red terminal bar. Use the Jandy Multiplex PCB, p/n 6584, when more than two of the 4-wire cables are used with the system.
Page 4
Ensure all low voltage wiring that runs outside the house or Power Center is connected to a surge suppression board before it connects to other PCBs. CAUTION Proper bonding and grounding is necessary for surge suppression to protect the AquaLink RS system. Jandy Power Center Enclosure...
Page 5
Page 5 To Spa Side Switch #1 Surge Suppression Interface PCB JANDY AquaLink RS 01/31/00 MON 6:00 PM POOL 65°F 79°F EQUIPMENT ON/OFF ONETOUCH ON/OFF MENU / HELP Power Center Surge Suppression Board Assbly . #6941 (mount in Daughter Card...