TROUBLESHOOTING - TRANSFORMER VOLTAGE
19
1000
DCV
200
20
2
200m
2000K
200K
20K
W
NPN
PNP
Third Test:
Set the meter to 200 ACV or higher. Put the leads on VAC 1 & VAC 2 of the 19 VAC
test points. The voltage should be between 17 to 24.
If no voltage is present, check 1 Amp Fuse on PIB.
If the voltage is outside the above range, replace the Transformer.
Notes:
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
ACV
OFF
750
200
DCA
200µ
2000µ
20m
200m
10A
h
FE
2K
200
+24 VDC
VAC 1
+12 VDC
19 VAC
+5 VDC
VAC 2
COMMON
18
1 Amp FUSE
65 VAC
75 VAC