Instrument Upgrades

Fast license-key upgrades for performance options that do not require additional
hardware:
1.
Place an order for the upgrade with Keysight and request to receive the option
upgrade entitlement certificate and a one-time software upgrade license through
email
2.
Redeem the certificate through the Web by following the instructions on the
certificate
3.
Install the license file and latest software in the CXA
4.
Begin using the new capability
Installation and testing information is available at:
www.keysight.com/find/cxa_upgrades
Description
Increase analysis bandwidth
from 10 to 25 MHz
Add preamplifier, 3 GHz
Add preamplifier, 7.5 GHz
Add preamplifier, 13.6 GHz
Add preamplifier, 26.5 GHz
Add fine resolution
step attenuator
Upgrade to the precision
frequency reference
Add tracking generator, 3 GHz
Add tracking generator, 6 GHz
Add basic EMI
precompliance features
Add external source control
Add second IF output
Add enhanced display package
Add security features,
exclude launch program
Add security features,
prohibit saving results
Add removable solid state
drive
1. At the time of manufacture, the hardware related to many of these options was fully adjusted and the option performance was verified to be within its
warranted specifications. Within one year of the initial calibration date of the analyzer, this option is fully calibrated with no further adjustment or
verification testing.
2. If this analyzer has been adjusted as part of a repair or calibration during its first year, or if the analyzer is more than one year old, additional adjustment and
performance verification tests are required to ensure that some newly installed options are functioning properly. However, the completion of these tests
does not guarantee that the analyzer meets all warranted specifications.
For more information on accessories go to: www.keysight.com/find/accessories
1, 2
Upgrade
Requirements CXA must
number
already include the
following)
N9000BU-B25
None
N9000BU-P03
None
N9000BU-P07
507, 513 or 526
N9000BU-P13
513 or 526
N9000BU-P26
526
N9000BU-FSA
None
N9000BU-PFR
None
N9000BU-T03
None
N9000BU-T06
None
N9000BU-EMC
None
N9000BU-ESC
None
N9000BU-CR3
None
N9000BU-EDP
None
N9000BU-SF1
None
N9000BU-SF2
None
N9000BU-SSD
None
You Can Upgrade!
Options can be added after your
initial purchase.
Most X-Series
options are license-
key upgradeable.
Additional information
Not compatible with Option 503
Not compatible with Option 503 or 507
Not compatible with Option 503, 507, or 513
Requires hardware and license key; not compatible with Options 513
or 526
Requires hardware and license key; not compatible with Options 503,
513, or 526
Adds feature to control the Keysight EXG, MXG, and PSG signal
generators; includes 3 BNC cables and 1 cross-over LAN cable; not
compatible with Options 513 or 526
Requires hardware and license key; not compatible with Options 513
or 526
Prevents the launching of Windows programs from
the instrument application
Prevents the saving/recall of measurement results or user
configurations to/from instrument's data storage
Provides a fully-imaged, removable solid-state drive