Download Print this page

Instrument Upgrades - Keysight Technologies MXA N9020A-508 Configuration Manual

Mxa x-series signal analyzer

Advertisement

11 | Keysight | MXA X-Series Signal Analyzer N9020A - Configuration Guide

Instrument Upgrades

Fast license-key upgrades for performance options that do not require additional
hardware:
1.
Place an order for the upgrade with Keysight and request to receive the
option upgrade entitlement certificate and a one-time software upgrade
license through email
2.
Redeem the certificate through the Web by following the instructions on
the certificate
3.
Install the license file and latest software in the MXA
4.
Begin using the new capability
Installation and testing information is available at:
www.keysight.com/find/mxa_upgrades
Upgrades for analysis bandwidth depend on the vintage of the instrument and the options already installed. More than one option may
be required to achieve desired wider analysis bandwidth. Use our web-based calculator to find the upgrade options you may need:
www.keysight.com/find/BW-selector
Description
Increase frequency from 3.6 to 8.4 GHz
Increase frequency from 3.6 to 13.6 GHz
Increase frequency from 3.6 to 26.5 GHz
Increase frequency from 8.4 to 13.6 GHz
Increase frequency from 8.4 to 26.5 GHz
Increase frequency from 13.6 to 26.5 GHz
Increase analysis bandwidth from
10 MHz to 25 MHz
Increase analysis bandwidth from
10 to 40 MHz
Increase analysis bandwidth from
25 to 40 MHz
Increase analysis bandwidth to 40 MHz.
Option 508, 513, and 526 only
Increase analysis bandwidth to 40 MHz,
Option 503 only
Increase analysis bandwidth from
10/25 MHz to 85 MHz; Option 503 only
Increase analysis bandwidth from
10/25 MHz to 85 MHz; Option 508, 513,
and 526 only
1. At the time of manufacture, the hardware related to many of these options was fully adjusted and the option performance was verified to be within its
warranted specifications. Within two years of the initial calibration date of the analyzer, this option is fully calibrated with no further adjustment or
verification testing.
2. If this analyzer has been adjusted as part of a repair or calibration during its two years, or if the analyzer is more than two years old, additional adjustment
and performance verification tests are required to ensure that some newly installed options are functioning properly. However, the completion of these tests
does not guarantee that the analyzer meets all warranted specifications.
3. This upgrade option is for instrument(s) ordered before May 1, 2011.
1, 2
Upgrade
Requirements
number
(MXA must already include the
following)
N9020AK-F01
503
N9020AK-F02
503
N9020AK-F03
503
N9020AK-F06
508
N9020AK-F07
508
N9020AK-F10
513
N9020AK-B25
None
3
N9020AK-B40
DP2 or MPB
N9020AK-BU1
B25 and DP2 or MPB
N9020AK-HL4
508, 513, or 526
Serial prefix < US/SG/MY5233
N9020AK-HLA
508, 513, or 526
Serial prefix ≥ US/SG/MY5233
N9020AK-HL8
503
Serial prefix < US/SG/MY5233
N9020AK-HL9
503
Serial prefix ≥ US/SG/MY5233
N9020AK-HLD
503
Serial prefix < US/SG/MY5233
N9020AK-HLE
508, 513, 526
Serial prefix < US/SG/MY5233
You can upgrade!
Options can be
added after your
initial purchase.
All of our X-Series
application options
are license-key upgradeable.
Additional information
Also enables 25 MHz per channel baseband
bandwidth if Option BBA is installed
Also enables 40 MHz per channel baseband
bandwidth if Option BBA is installed
Also enables 40 MHz per channel baseband
bandwidth if Option BBA is installed
Includes hardware and license key; also adds
microwave preselector bypass and enables 40 MHz
per channel baseband bandwidth if Option BBA is
installed; not compatible with Option 503
Includes hardware and license key; also enables
40 MHz per channel baseband bandwidth if Option
BBA is installed; only compatible with Option 503
Includes hardware and license key; only compatible
with Option 503; not compatible with Option BBA
Includes hardware and license key; also add
microwave preselector bypass; only compatible with
Option 508, 513, 526; not compatible with Option
BBA

Advertisement

loading

This manual is also suitable for:

Mxa n9020a-503Mxa n9020a-526Mxa n9020a-513