Download Print this page

Get More Information - Keysight Technologies N9000B Configuration Manual

Cxa x-series signal analyzer, multi-touch

Advertisement

02 | Keysight | N9000B CXA X-Series Signal Analyzer, Multi-touch - Configuration Guide
Configure Your Keysight CXA Signal Analyzer
This step-by-step process will help you configure your new CXA X-Series signal analyzer.
Tailor the performance to meet your requirements.
Included in base product
Standard options and accessories come with the CXA base model at no additional
charge and do not need to be ordered. They include:
– Spectrum analyzer measurement application
– Dual-core, high-performance processor, 8 GB RAM, removable solid-state drive
– Frequency reference
– 10 MHz analysis bandwidth
– Enhanced phase noise
– Windows Embedded Standard 7
– Benchtop configuration
– Mouse
– User guide
– Power cord
– 3-year return-to-Keysight warranty
Step 1. Select maximum frequency range (required option; frequency range not upgradeable)
Description
Frequency range, 9 kHz to 3.0 GHz
Frequency range, 9 kHz to 7.5 GHz
Frequency range, 9 kHz to 13.6 GHz
Frequency range, 9 kHz to 26.5 GHz
Step 2. Add a preamplifier
Description
Preamplifier, 100 kHz to 3.0 GHz
Preamplifier, 100 kHz to 7.5 GHz
Preamplifier, 100 kHz to 13.6 GHz
Preamplifier, 100 kHz to 26.5 GHz
Step 3. Choose frequency reference
Description
Frequency reference
Precision frequency reference
Step 4. Choose an attenuator
Description
Mechanical attenuator
Fine resolution step attenuator
Step 5. Choose analysis bandwidth
Description
10 MHz analysis bandwidth
25 MHz analysis bandwidth
Option number
Additional information
N9000B-503
N9000B-507
N9000B-513
N9000B-526
Option number
Additional information: Preamplifiers improve the noise floor for low-level signal
detection; +20 dB: 100 kHz to 26.5 GHz
N9000B-P03
Compatible with N9000B-503, N9000B-507, N9000B-513,
and N9000B-526
N9000B-P07
Compatible with N9000B-507, N9000B-513, and N9000B-526
N9000B-P13
Compatible with N9000B-513 and N9000B-526
N9000B-P26
Compatible with N9000B-526
Option number
Additional information
Standard
Aging rate: ± 1 x 10
N9000B-PFR
Reduces frequency drift for more accurate measurements; aging rate: ± 1 x 10
Option number
Additional information
Standard
10 dB steps, 0 to 50 dB, for N9000B-503 and N9000B-507
10 dB steps, 0 to 70 dB, for N9000B-513 and N9000B-526
N9000B-FSA
Allows 2 dB steps for the full range of the attenuator
Option number
Additional information
Standard
Useful for most 2G and 3G measurement applications
N9000B-B25
Extends the analysis (demod) bandwidth from 10 to 25 MHz; useful for most cellular
communications, wireless connectivity, and audio/video broadcasting measurement
applications

Get More Information

For a summary of specifications,
refer to the N9000B CXA data
sheet (literature number 5992-
1274EN ).
A full set of specifications are
available in the N9000B CXA
Signal Analyzer Specification
Guide at www.keysight.com/find/
cxa_specifications.
/year
–6
/year
–7

Advertisement