Thresholds; Digital Measurements - Triax MCT 080 User Manual

Mct 08x series
Table of Contents

Advertisement

FIELD METERS MCT 080 / 081 / 082 / 085 USER MANUAL
10.5

Thresholds

Predefined thresholds are used to assess if the measurement is pertinent.
Decision thresholds are used to display the measures « Power Level » and « Measurement Map »:
10.6

Digital measurements

In digital standards, in addition to the RF level and to the C/N hereabove, the appliance also displays :
different BER (Bit Error Rate): ratio false bits / transmitted bits
-
the Packet Error Rate (PER): ratio false packets / transmitted packets
-
-
the MER (Modulation Error Ratio): digital signal-to-noise ratio
LKM (Link Margin): difference between measured MER and MER before unlocked
-
(this is the margin available before unlocking.)
The bargraphs are displayed with colors depending on the measured error rates:
-
-
-
An automatic frequency check (AFC) is automatically activated in error rate measurement
mode.
Standard
Analogical terrestrial TV
DVB-C/C2, J83B
DVB-T/T2
DAB-DAB+
FM, carrier
Analogical satellite TV
DVB-S, DSS
DVB-S2
min threshold
GREEN: good error rates
-4
ORANGE: BERo > 10
(QEF : Quasi Error Free) without lost packet
RED: lost packets (PER).
Min
Max
57
74
57
74
35
70
35
70
50
66
47
77
47
77
47
77
max threshold
p.
55

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mct 081Mct 082Mct 085

Table of Contents