V, Dbµv, Dbmv Et Dbm Conversion; Typical Values For Measurements - Triax MCT 080 User Manual

Mct 08x series
Table of Contents

Advertisement

FIELD METERS MCT 080 / 081 / 082 / 085 USER MANUAL
35.7
V, dBµV, dBmV et dBm conversion
dBμV (dBmV) is a logarithmic ratio between a measured voltage Ud and a reference voltage Ur.
The reference voltage is Ur = 1 μV (1 mV)
N = 20 log (Ud/Ur)
dBm is a logarithmic ratio between a measured power Pd and a reference power Pr.
The reference power is Pr = 1 mW into 75 ohms.
N = 10 log (Pd/Pr) with Pd = Ud2 / 75
U
= 1 µV
d
U
= 1 mV
d
U
= 1 V
d
35.8

Typical values for measurements

Values given are indicatives, minimum and maximum for good signal quality
Measurements
Terrestrial
Analog TV
FM
DAB/DAB+
DVB-T/H
DVB-T2
DVB-C
J83B
Satellite
Analog TV
DVB-S, DSS
DVB-S2
N = 0 dBµV
N = 60 dBµV
N = 120 dBµV
Level, power (dBµV)
mini
maxi
57
74
50
66
35
70
35
70
35
70
57
74
57
74
47
77
47
77
47
77
N = - 60 dBmV
N = -108.75 dBm
N = 0 dBmV
N = -48.75 dBm
N = 60 dBmV
N = 11.25 dBm
C/N
BER
(dB)
> 45
-
> 38
-
E
BER < 2
-4
E
> 26
VBER < 2
-4
E
> 22
FER < 2
-7
E
> 31
BER < 2
-4
E
> 31
BER < 2
-4
> 15
-
E
> 11
VBER < 2
-4
E
> 8
PER < 1
-7
p.
141
MER
modulation
(dB)
-
-
-
-
-
2K
> 26
8K, 64QAM, 1/32, 2/3
> 22
32K, 256QAM, 1/8, 2/3
> 31
64QAM
> 31
64QAM
-
-
> 11
QPSK, 3/4
> 8
8PSK, 2/3