Technical Data; Pump Dimensions; Electrical Specifications; Pump Performance Curves (Intelliflo I1) - Pentair IntelliFlo Installation And User Manual

Variable speed pump
Table of Contents

Advertisement

26

TECHNICAL DATA

Pump Dimensions

Electrical Specifications

Circuit Protection: Two-pole 20 AMP device at the Electrical Panel.
Input: 230 VAC, 50/60 Hz, 3200 Watts Maximum, 1 phase
Note: Refer to the pump motor label, and all national and local
electrical codes, for specific electrical requirements and specifications.
Pump Performance Curves (IntelliFlo i1 Pumps)
90
80
70
SPEED 4
60
50
40
SPEED 3
30
20
SPEED 2
10
SPEED 1
B C
A
0
0
20
FLOW RATE IN US GALLONS PER MINUTE
INTELLIFLO
Variable Speed Pump Installation and User's Guide
®
J
I
G
H
F
E
D
40
60
S
Q
R
P
O
N
L
M
K
80
100
WEF VALUES
011028
WEF 6.1 THP 3.95
011059
WEF 7.5 THP 3.95
011060
WEF 6.9 THP 3.95
CURVE
SPEED
A
450 RPM
B
660 RPM
C
750 RPM
D
850 RPM
E
1050 RPM
F
1250 RPM
G
1500 RPM
H
1725 RPM
I
1850 RPM
J
2050 RPM
K
2250 RPM
L
2350 RPM
M
2450 RPM
N
2550 RPM
O
2650 RPM
P
2850 RPM
Q
3110 RPM
R
3250 RPM
S
3450 RPM
120

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents