MENU
Pump Menu: Speeds 1-8
SPEED 1-8
Set Speeds 1-8 in Schedule Mode
Programming Schedule for Constant Run
A speed cannot be programmed with the same start
and stop times. To run a speed without stopping, set
the Start time one minute after the stop time.
Example: A single speed will run non stop if programmed
with a Start Time of 8:00 AM and a Stop time of 7:59 AM.
12:15p
Schedule
Set Speed
Note: The pump will not run the scheduled speeds until the
Start/Stop button is pressed (LED on) to place the pump in
Schedule mode.
Note: When two speeds are scheduled during the
same run time the pump will run the higher RPM Speed
regardless of Speed # in use.
Note: The most recent command, Manual or Schedule,
takes priority regardless of speed number RPM.
Manual
Speed 1 (1-4)
Schedule
(cont.)
Egg Timer
Disabled
Speed 5 (5-8)
Schedule
12:15p
750 RPM
T 1:05 150 WATTS
Running Speed 1
MENU
EXT CONTROL
Set Speed - Default: MANUAL
Set Speed
Set Start Time

External Control

Set Stop Time
Set Speed
This function is for programming speeds that will run
Time
when the automation control system sends it a command.
Default: Disabled
For example, Terminal 3 and 4 in the automation system
will correspond to External Control Program #1. (5 and
Set Speed
Set Start Time
6 to Ext Ctrl #2).
Set Stop Time
The Stop Delay feature allows the user to program the
pump to run a Program Speed after the External Control
has been deactivated. This feature can be used to provide
a cooling down period for the pump after a trigger signal
from an installed heater has been deactivated. Each
individual Program Speed can have a Stop Delay of 1
to 10 minutes programmed.
Use the External Control feature to program the
IntelliComm system power center.
To access the External Control menu:
1. Check that the green power LED is on.
2. Press the Menu button.
3. Use Up or Down arrow to scroll to "Ext. Ctrl.".
4. Press Select. "Program 1" is displayed.
5. Press Select. "750 RPM' is displayed.
6. Press Select. The "RPM" number will highlight.
7. Press Up or Down arrow to change the RPM
setting.
8. Press Save to save the setting.
Note: To cancel any changes, press the Back
button to exit without saving.
9. If you do not wish to program a Stop Delay,
continue to step 13. If you do wish to program a
Stop delay press Up or Down arrow to scroll to
"Stop Delay".
10. Press Select to set Stop Delay.
11. Press Up or Down arrows to change the Stop
Delay setting. Stop Delay can be set from 0
minutes (disabled) to 10 minutes.
12. Press Save to save the setting.
Note: To cancel any changes, press the Back
button to exit without saving.
13. Press Back to return to set Program 2.
14. Use Up or Down arrow to scroll to "Program 2".
15. Repeat Steps 5 through 13 to set Program 2, 3,
and 4.
INTELLIFLO
Variable Speed Pump Installation and User's Guide
®
Pump Menu: External
Speed - Default: 750 RP
Program 1
Control
Speed - Default: 1500 R
Program 2
Speed - Default: 2350 R
Program 3
Program 4
Speed - Default: 3110 R
13