Modbus
Description
address
43121
Digital I/O 1 – Type
43122
Digital I/O 1 – Source
43123
Digital I/O 1 – Polarity
43124
Digital I/O 2 – Type
43125
Digital I/O 2 – Source
43126
Digital I/O 2 – Polarity
43127
Digital I/O 3 – Type
43128
Digital I/O 3 – Source
43129
Digital I/O 3 – Polarity
43130
Digital I/O 4 – Type
43131
Digital I/O 4 – Source
43132
Digital I/O 4 – Polarity
43133
Digital I/O 5 – Type
43134
Digital I/O 5 – Source
43135
Digital I/O 5 – Polarity
43136
Digital I/O 6 – Type
43137
Digital I/O 6 – Source
43138
Digital I/O 6 – Polarity
Table B.28: Digital I/O settings
Modbus
Description
address
43139
Relay 1 – Source
43140
Relay 1 – Polarity
43141
Relay 2 – Source
43142
Relay 2 – Polarity
43143
Relay 3 – Source
43144
Relay 3 – Polarity
43145
Relay 4 – Source
43146
Relay 4 – Polarity
43147
Relay 5 – Source
43148
Relay 5 – Polarity
43149
Relay 6 – Source
43150
Relay 6 – Polarity
Table B.29: Relay settings
Valid range
0 – Off
1 – Digital output
2 – Digital input (volt-free)
3 – Digital input (24 V)
0, and 9 to 52 (output)
0, and 53 to 60 (input)
See Table C.3, page 52.
0 – Inverted
1 – Non inverted
See Digital I/O 1 – Type
See Digital I/O 1 – Source
0 – Inverted
1 – Non inverted
See Digital I/O 1 – Type
See Digital I/O 1 – Source
0 – Inverted
1 – Non inverted
See Digital I/O 1 – Type
See Digital I/O 1 – Source
0 – Inverted
1 – Non inverted
See Digital I/O 1 – Type
See Digital I/O 1 – Source
0 – Inverted
1 – Non inverted
See Digital I/O 1 – Type
See Digital I/O 1 – Source
0 – Inverted
1 – Non inverted
Valid range
0, and 9 to 44 and 49 to 53
See Table C.3, page 52
0 – inverted
1 – Non inverted
See Relay 1 – Source
0 – inverted
1 – Non inverted
See Relay 1 – Source
0 – inverted
1 – Non inverted
See Relay 1 – Source
0 – inverted
1 – Non inverted
See Relay 1 – Source
0 – inverted
1 – Non inverted
See Relay 1 – Source
0 – inverted
1 – Non inverted
B.13 Writable strings
Modbus
Description
address
44000
Instrument tag
44016
Process tag 1
44032
Process tag 2
44048
Process tag 3
44064
Process tag 4
44080
Alarm 1 tag
44096
Alarm 2 tag
44112
Alarm 3 tag
44128
Alarm 4 tag
44144
Alarm 5 tag
44160
Alarm 6 tag
44176
Alarm 7 tag
44192
Alarm 8 tag
Table B.30: 16 byte strings
Modbus
Description
address
44208
Chart config tag 1
44211
Chart config tag 2
44214
Chart config tag 3
44217
Chart config tag 4
Table B.31: 3 byte strings
Navigator 540 | Transmitter | COM/AWT540/PB–EN Rev. C
Default
Navigator 540
Tag 1
Tag 2
Tag 3
Tag 4
Alarm 1
Alarm 2
Alarm 3
Alarm 4
Alarm 5
Alarm 6
Alarm 7
Alarm 8
Default
Ch 1
Ch 2
Ch 3
Ch 4
51