ABB Navigator 540 Instruction Manual page 38

Hide thumbs Also See for Navigator 540:
Table of Contents

Advertisement

Description
Slot
Index
Digital I/O 1 – Type 120
121
Digital I/O 1 –
120
122
Source
Digital I/O 1 –
120
123
Polarity
Digital I/O 2 – Type 120
124
Digital I/O 2 –
120
125
Source
Digital I/O 2 –
120
126
Polarity
Digital I/O 3 – Type 120
127
Digital I/O 3 –
120
128
Source
Digital I/O 3 –
120
129
Polarity
Digital I/O 4 – Type 120
130
Digital I/O 4 –
120
131
Source
Digital I/O 4 –
120
132
Polarity
Digital I/O 5 – Type 120
133
Digital I/O 5 –
120
134
Source
Digital I/O 5 –
120
135
Polarity
Digital I/O 6 – Type 120
136
Digital I/O 6 –
120
137
Source
Digital I/O 6 –
120
138
Polarity
Table A.32: Digital I/O settings
38
COM/AWT540/PB–EN Rev. C | Navigator 540 | Transmitter
Object
Data type
Bytes
type
Simple
Unsigned 8
1
Simple
Unsigned 8
1
Simple
Unsigned 8
1
Simple
Unsigned 8
1
Simple
Unsigned 8
1
Simple
Unsigned 8
1
Simple
Unsigned 8
1
Simple
Unsigned 8
1
Simple
Unsigned 8
1
Simple
Unsigned 8
1
Simple
Unsigned 8
1
Simple
Unsigned 8
1
Simple
Unsigned 8
1
Simple
Unsigned 8
1
Simple
Unsigned 8
1
Simple
Unsigned 8
1
Simple
Unsigned 8
1
Simple
Unsigned 8
1
Store
Access
Default
D
R/W
Off
D
R/W
None
D
R/W
Non
inverted
D
R/W
Off
D
R/W
None
D
R/W
Non
inverted
D
R/W
Off
D
R/W
None
D
R/W
Non
inverted
D
R/W
Off
D
R/W
None
D
R/W
Non
inverted
D
R/W
Off
D
R/W
None
D
R/W
Non
inverted
D
R/W
Off
D
R/W
None
D
R/W
Non
inverted
Valid
Notes
range
0 to 3
0 – Off
1 – Digital output
2 – Digital input (voltage-free)
3 – Digital input (24 Volt)
0 and
See source list
9 to 64
0 to 1
0 – Inverted
1 – Non inverted
0 to 3
0 – Off
1 – Digital output
2 – Digital input (voltage-free)
3 – Digital input (24 Volt)
0 and
0 – None
9 to 64
1 – Sensor 1 concentration
2 – Sensor 2 concentration
3 – Sensor 3 concentration
4 – Sensor 4 concentration
5 – Sensor 1 temperature
6 – Sensor 2 temperature
7 – Sensor 3 temperature
8 – Sensor 4 temperature
0 to 1
0 – Inverted
1 – Non inverted
0 to 3
0 – Off
1 – Digital output
2 – Digital input (voltage-free)
3 – Digital input (24 Volt)
0 and
See source list
9 to 64
0 to 1
0 – Inverted
1 – Non inverted
0 to 3
0 – Off
1 – Digital output
2 – Digital input (voltage-free)
3 – Digital input (24 Volt)
0 and
See source list
9 to 64
0 to 1
0 – Inverted
1 – Non inverted
0 to 3
0 – Off
1 – Digital output
2 – Digital input (voltage-free)
3 – Digital input (24 Volt)
0 and
See source list
9 to 64
0 to 1
0 – Inverted
1 – Non inverted
0 to 3
0 – Off
1 – Digital output
2 – Digital input (voltage-free)
3 – Digital input (24 Volt)
0 and
See source list
9 to 64
0 to 1
0 – Inverted
1 – Non inverted

Advertisement

Table of Contents
loading

Table of Contents