B.11 Writable, 16 bits
Modbus
Description
address
42000
Sensor 1 – Recovery time
42001
Sensor 1 –
Salinity correction
42002
Sensor 1 –
Pressure compensation
42003
Sensor 1 – Grab sample sampling
time
42004
Sensor 2 – Recovery time
42005
Sensor 2 –
Salinity correction
42006
Sensor 2 –
Pressure compensation
42007
Sensor 2 – Grab sample sampling
time
42008
Sensor 3 – Recovery time
42009
Sensor 3 –
Salinity correction
420010
Sensor 3 –
Pressure compensation
420011
Sensor 3 – Grab sample sampling
time
420012
Sensor 4 – Recovery time
420013
Sensor 4 –
Salinity correction
420014
Sensor 4 –
Pressure compensation
420015
Sensor 4 – Grab sample sampling
time
420016
Stream sample rate
Table B.19: Writable 16 bits
Modbus
Description
address
42017
Alarm 1 – Time hysteresis
42018
Alarm 2 – Time hysteresis
42019
Alarm 3 – Time hysteresis
42020
Alarm 4 – Time hysteresis
42021
Alarm 5 – Time hysteresis
42022
Alarm 6 – Time hysteresis
42023
Alarm 7 – Time hysteresis
42024
Alarm 8 – Time hysteresis
Table B.20: Alarm time hysteresis
46
COM/AWT540/PB–EN Rev. C | Navigator 540 | Transmitter
B.12 Writable, 8 bits
Notes
Modbus
address
43000
Low level dissolved
oxygen sensors only
43001
Sodium sensors only
43002
Low level sensors
dissolved oxygen only
43003
43004
Sodium sensors only
43005
Low level sensors
43006
dissolved oxygen only
43007
Sodium sensors only
Low level dissolved
oxygen sensors only
Sodium sensors only
43008
Sodium multi-stream
sensor only
43009
Notes
Valid range 0 to 9999
seconds
43010
43011
Table B.21: Single-stream sensors – Units, filter and
scheduled calibration configuration
Description
Transmitter – Temperature
units
Sensor 1 – Concentration
units
Sensor 1 – Filter type
Sensor 1 – Filter time
Sensor 1 – Wetting routine
procedure
Sensor 1 – Flow measurement
Sensor 1 – Out of sample
detection
Sensor 1 – Scheduled
calibration type
Sensor 1 – Scheduled
calibration frequency units
Sensor 1 – Scheduled
calibration frequency daily
Sensor 1 – Scheduled
calibration frequency weekly
Sensor 1 – Scheduled
calibration frequency monthly
Valid range
13 – Deg.C
14 – Deg. F
7 – ppb
8 – ug/l
9 – ug/Kg
0 – Off
1 – Minimum value
2 – Maximum value
3 – Average value
4 – Sliding average
5 to 100 Samples / Seconds
0 – Disabled
1 – Enabled
0 – Disabled
1 – Enabled
0 – Disabled
1 – Enabled
0 – Scheduled calibration
disabled
1 – One point calibration
(low standard)
2 – One point calibration
(high standard)
3 – Two point calibration
4 – Regeneration + two point
calibration
5 – One point air calibration
0 – Frequency off
1 – Daily
2 – Weekly
3 – Monthly
0 – Daily
1 – Two days
2 – Three days
3 – Four days
4 – Five days
5 – Six days
6 – Seven days
0 – Weekly
1 – Two weeks
2 – Three weeks
3 – Four weeks
4 – Five weeks
5 – Six weeks
6 – Seven weeks
7 – Eight weeks
0 – Monthly
1 – Two months
2 – Three months
3 – Four months
4 – Six months
5 – Twelve months