Modbus
Description
address
43035
Sensor 4 – Filter type
43036
Sensor 4 – Filter time
43037
Sensor 4 – Wetting routine
procedure
43038
Sensor 4 – Flow measurement
43039
Sensor 4 – Out of sample
detection
43040
Sensor 4 – Scheduled
calibration type
43041
Sensor 4 – Scheduled
calibration frequency units
43042
Sensor 4 – Scheduled
calibration frequency daily
43043
Sensor 4 – Scheduled
calibration frequency weekly
43044
Sensor 4 – Scheduled
calibration frequency monthly
Table B.21: Single-stream sensors – Units, filter and
scheduled calibration configuration (continued)
48
COM/AWT540/PB–EN Rev. C | Navigator 540 | Transmitter
Valid range
0 – Off
1 – Minimum value
2 – Maximum value
3 – Average value
4 – Sliding average
5 to 100 Samples / Seconds
0 – Disabled
1 – Enabled
0 – Disabled
1 – Enabled
0 – Disabled
1 – Enabled
0 – Scheduled calibration
disabled
1 – One point calibration
(low standard)
2 – One point calibration
(high standard)
3 – Two point calibration
4 – Regeneration + two point
calibration
5 – One point air calibration
0 – Frequency off
1 – Daily
2 – Weekly
3 – Monthly
0 – Daily
1 – Two days
2 – Three days
3 – Four days
4 – Five days
5 – Six days
6 – Seven days
0 – Weekly
1 – Two weeks
2 – Three weeks
3 – Four weeks
4 – Five weeks
5 – Six weeks
6 – Seven weeks
7 – Eight weeks
0 – Monthly
1 – Two months
2 – Three months
3 – Four months
4 – Six months
5 – Twelve months
Modbus
Description
address
43045
Transmitter – temperature
units
43046
Concentration units
43047
Filter type
43048
Filter time
43049
Wetting routine procedure
43050
Stream 1 – Flow measurement
43051
Stream 2 – Flow measurement
43052
Stream 3 – Flow measurement
43053
Out of sample detection
43054
Stream sequence - Position 1
43055
Stream sequence - Position 2
43056
Stream sequence - Position 3
43057
Stream sequence - Position 4
43058
Stream sequence - Position 5
43059
Stream sequence - Position 6
Table B.22: Multi-stream sensors – units, filter and
scheduled calibration configuration
Valid range
13 - Deg.C
14 - Deg. F
7 – ppb
8 – ug/l
9 – ug/Kg
0 – Off
1 – Minimum value
2 – Maximum value
3 – Average value
4 – Sliding average
5 to 100 Samples / Seconds
0 – Disabled
1 – Enabled
0 – Disabled
1 – Enabled
0 – Disabled
1 – Enabled
0 – Disabled
1 – Enabled
0 – Disabled
1 – Enabled
0 to 3
0 – End of sequence
1 – Stream 1
2 – Stream 2
3 – Stream 3
0 to 3
0 – End of sequence
1 – Stream 1
2 – Stream 2
3 – Stream 3
0 to 3
0 – End of sequence
1 – Stream 1
2 – Stream 2
3 – Stream 3
0 to 3
0 – End of sequence
1 – Stream 1
2 – Stream 2
3 – Stream 3
0 to 3
0 – End of sequence
1 – Stream 1
2 – Stream 2
3 – Stream 3
0 to 3
0 – End of sequence
1 – Stream 1
2 – Stream 2
3 – Stream 3