Chapter 3 Setup
4. After a while, the following message appears on the screen. The description of message is subject to
the hardware configuration.
Press <F2> SETUP, <F3> Internal Flash Memory, <F4> ROM Utility, <F12> Network
You can call the functions below upon completion of POST by pressing the following function keys.
<F2> key: Run BIOS Setup Utility (SETUP). See Chapter 3 (2. BIOS Setup Utility (SETUP)) for
<F3> key: Run EXPRESSBUILDER from Internal Flash Memory.
<F4> key: Run Offline Tools. See Chapter 1 Maintenance (9. Offline Tools) in "Maintenance Guide"
<F12> key: Boot from network.
5. When Legacy is specified for Boot Mode, if a controller which has its BIOS such as a RAID controller
is installed, a message that prompts you to start the dedicated utility to configure the card is displayed.
Example: If an optional RAID controller is installed
Press <Ctrl> <R> to Run MegaRAID Configuration Utility
The utility starts by pressing <Ctrl> + <R> keys.
For details on the utility, refer to the manual supplied with each optional board.
Depending on the hardware configuration (optional boards), the message "Press Any Key" might
appear to prompt a key entry. Continue to operate after checking the manual of the optional board.
6. The OS starts when POST is completed.

POST error messages

1.1.2
When POST detects an error, an error message appears on the screen or a beep code sounds. For
descriptions of error messages, causes, and countermeasures, see Chapter 3 (1. POST Error Message) in
"Maintenance Guide".
details.
See Chapter 3 (4. EXPRESSBUILDER) for details.
Note
If bootable CD/DVD is inserted into optical disk drive, the system starts from
CD/DVD even if <F3> key is pressed.
for details.
Tips
If One time or Always is specified for Power Management Policy in Server
menu of BIOS SETUP, a message indicating power consumption is being
measured is displayed instead of the message shown above. Wait for a while until
measurement is complete.
Note
Take notes on the indication displayed on display unit before consulting with your
sales representative. Alarm messages are useful information for maintenance.