6.4 Readout menu

The readout menu can be used to call up a number of current
sensor values to obtain more information on the appliance's
performance. Modifying values or settings is not possible in
this menu. The readout menu is displayed as follows:
1. In operating mode, press the ' Menu ' key. Now the display
shows the settings menu.
operating mode
settings menu
2. Use the '+' and '-' keys to go to the readout menu.
readout menu
Step no. readout value
01
02
03
04
05
06
07
08
09
10
11
12
13
16
Chapter 6
Description readout value
Current temperature from dwelling
Current temperature outdoor sensor
Bypass status (ON = bypass function active, OFF = bypass function not active)
Status frost protection (ON = frost protection active, OFF = frost protection not active)
Current channel pressure supply
Current duct pressure extract
Current relative humidity (option)
Readout CO
sensor 1 (CO
2
Readout CO
sensor 2 (CO
2
Readout CO
sensor 3 (CO
2
Readout CO
sensor 4 (CO
2
Renovent Excellent 180
Display layout
3. Activate the readout menu.
4
Use the '+' and the '-' key to scroll through the readout
menu'.
5
Press the 'R' key twice to go to operating mode.
If no key is operated during 5 minutes, the appliance auto-
matically returns to operating mode.
sensor only as an option for Plus version)
2
sensor only as an option for Plus version)
2
sensor only as an option for Plus version)
2
sensor only as an option for Plus version)
2
Rev. E
readout value
Step no. readout value;
refer to the table below
for an explanation
operating mode
2x
Unit
°C
o
C
Pa
Pa
m
3
/h
3
m
/h
PPM
PPM
PPM
PPM