Page 3
Renovent Sky 150 (Plus) STORE NEAR THE APPLIANCE This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
Scope of delivery Before starting installation of the heat recovery unit, check that it has been supplied complete and undamaged. The scope of delivery of the heat recovery unit Renovent Sky 150 includes the following components: 1: Heat recovery appliance 2: Wall mounting bracket kit;...
Page 7
482 mm Silencer- / air distribution box 100 x 50 mm (12x) 423012 200 mm 660 mm 482 mm Silencer- / air distribution box 130 x 60 mm (12x) 423013 200 mm 660 mm 482 mm Servicetool 531961 Renovent Sky 150...
The Renovent Sky 150 comes ready to plug in with a 230 V mains plug. The appliance comes as standard with a control unit, but connection of a simple 4-way switch is possible as well.
Chapter 3 Version 3.1 Technical information Renovent Sky 150 Supply voltage [V/Hz] 230/50 Protection degree IP30 Dimensions (w x d x h) [mm] 1000 x 660 x 198 Duct diameter [mm] Ø125 External diameter condensate discharge [“] Weight [kg] 24,5...
1 To dwelling 2 To atmosphere 3 From dwelling 4 From atmosphere 5 Electric connections 6 Connection condensate discharge Fan graph Note: The value stated in the circle is the capacity per fan (in Watt) = [W] Renovent Sky 150...
16 Modular connector multiple switch 17 Service connector 18 Sleeve low voltage cable 19 Sleeve cable 230 V. postheater or extra preheater 20 Mains cable 230 V. 21 9-pole connector (only for Plus version) 22 Connector eBus Fall Protection front panel Renovent Sky 150...
See §9 for more information on the connection possibilities of connectors X14 and X15. Hole for gland to be mounted by installer (for sleeve cable postheater/ extra preheater). Renovent Sky 150...
Installation must take place under: and residential buildings. buildings. The Renovent Sky 150 can directly be mounted to the wall or The installation room must be frost-free. ceiling using the mounting brackets supplied for that purpose. Because of the appliance’s weight, mounting the possible to replace them in due course.
5 0 m m i n . 2 5 m 5 0 5 m i n . 2 5 m m i n . 1 0 0 m 6 7 0 Click! Appliance disconnecting from mounting bracket Condensate discharge Renovent Sky 150...
Before connecting the condensate discharge to the appliance, cannot be removed from the appliance for service pour water into the U-trap to create an air trap. purposes! 3/4” Detachable coupler Detachable coupler A > 60 mm Renovent Sky 150...
Page 17
Chapter 5 Installation 60 mm Renovent Sky 150...
Page 18
Chapter 5 Installation 60 mm Renovent Sky 150...
The control unit that comes as standard with the appliance must be connected to the eBus connector. This (detachable) 2-pole eBus connector is mounted on the outside of the appliance (see also §10.1). Cables to be connected by installer nr.1 nr.2 (wire diameter at least 0,34 mm Renovent Sky 150...
Ex factory the control module is set for the appliance is. Settings in the control unit software of the the English language. In the setting menu controlunit, §6.5.2, Renovent Sky 150 can be called up and changed with the aid you can choose a language. Right-hand ‘Right-hand setting knob’.
Chapter 6 Display View on Display When the Renovent Sky 150 is in operating mode, the con- trol unit display indicates a number of different values: Flow rate indicator eBus connection indicator Fan indicator 0 8 :30 Sonntag 23.01.12 Sunday...
4 available manuals (rotate to select and FILTER - Service menu §6.5.1 (Service menu) - Settings menu control unit §6.5.2 (Settings control unit) - Settings menu appliance §6.5.3 (Settings appliance) - Information menu installer §6.5.4 (Information install.) MAIN MENU Renovent Sky 150...
(E-code); an explanation of fault codes is shown in §7.2. If only 1 appliance is connected, then that one is the master appliance; no more appliances are shown in this list than are detected through the e eBus connection. Renovent Sky 150...
In this menu you can choose the active programme, in- cluding: DATE (Periods) every period. Language (Language) In this menu you can choose a language; ex factory the control module is set for the English language. LANGUAGE Renovent Sky 150...
INFORMATION MENU MAIN MENU - Current temperature outside (in °C) (T atmosph.) INSTALLER - Current relative humidity; only if installed an RH sensor (in %) (RH) In this menu you can only read out values, not modify them. Renovent Sky 150...
The (permanently lighted) display shows the fault symbol remedy this fault. A locking fault cannot be remedied by taking (spanner) together with fault code. The red LED on the multiple Warning and subsequently pulling the power plug. Renovent Sky 150...
If mode 2 of a multiple switch does not work, the modular connector of the multiple switch has been connected the wrong way round. Cut off one of the RJ connectors to the multiple switch and mount a new connector the other way round. Renovent Sky 150...
0 8 :0 0 2 3 :0 0 LED at the switch lights up. FILTER It is not permitted to use the appliance without 0 8 :30 Sunday Sonntag 23.01.12 0 8 :0 0 - 2 3 :0 0 FILTER Renovent Sky 150...
Chapter 8 Maintenance Maintenance installer Swing open the front panel (can also be taken from the hinges, if required). Renovent Sky 150...
Page 31
Chapter 8 Maintenance For ceiling mounting, carefully remove the condensate bin; Rinse the exchanger there may still be some condensate left in the condensate with hot water and a bin! regular detergent. max. 55 ºC Renovent Sky 150...
Page 33
Sunday Sonntag 23.01.12 0 8 :0 0 2 3 :0 0 FILTER Filter reset; see §6.5.1 Press the Return key ( ) to leave any selected menu and the appliance will return to operating mode. Clic k! Renovent Sky 150...
Indoor multiple control supply service Motor bypass pre-heater temperature extract fan temperature switch board connector valve sensor sensor external sensor 0-10 V RH-sensor control unit post-heater output 0-10V 24V. switch (optional) applicable post-heater input contact Renovent Sky 150...
1 or 2. The boost mode can be reset by putting the switch to setting 3 for longer than 2 seconds or by switching it to absence mode ( Renovent Sky 150...
Important: Because of polarity sensitivity, always connect contacts X1-1 to X1-1 and contacts X1-2 to X1-2. Never connect X1-1 and X1-2. A maximum of 10 appliances (1 Master + 9 Slave max.) 10.4 Cable sleeve Setting parameter 28 & 29 (§12) Renovent Sky 150...
) The strain reliever to be installed by the installer (not supplied with the appliance) for feeding the 230 volt cable to the postheater or extra preheater. 230V 50Hz Connection 230V extra preheater 50Hz Setting parameter 11 (§12) Renovent Sky 150...
Chapter 10 Electric connections accessories 10.6 Connection geo heat exchanger 30°C 25°C Minimum temperature Maximum temperature To dwelling To atmosphere From dwelling 15°C From atmosphere 10°C 3°C 0°C Setting parameter 25, 26 & 27 (§12) Renovent Sky 150...
Connections no. 3 and no. 4 standard 0-10 volt input; connections no. 1 and no. 2 can optionally be used as 0-10 volt input as well. Setting parameter 19, 20 & 21 (§12) Renovent Sky 150...
When ordering parts, in addition to the article code number Example (see exploded view), please state the type of the heat recovery appliance, the serial number, the year of production and the Appliance type : Renovent Sky 150 name of the part:: Serial number : 423000160201...
Page 41
Cable with power plug 230 volt * 533009 Heating coil 375 W preheater 533020 Control unit 510490 Air Control 510498 The mains cable has a print connector. When replacing it, always order a replacement mains cable Brink without prior notice. Renovent Sky 150...
Page 43
15,0 °C - 40,0 °C 0,5 °C (Above this temperature the valve opens.) FACTORY SETTING RENOVENT ADJUSTING RANGE OFF (= RH-sensor not active) RH-sensor ON (= RH-sensor active) +2 most sensitive Sensitivity 0 default setting RH-sensor RH-sensor -2 least sensitive Renovent Sky 150...
Page 44
Min. PPM eBus CO -sensor 3 Max. PPM eBus CO -sensor 3 1200 Min. PPM eBus CO -sensor 4 Max. PPM eBus CO -sensor 4 1200 Flow correction 100% 90% - 110% Default position switch 0 - 1 Renovent Sky 150...
Chapter 13 ErP-value Supplier: Brink Climate Systems B.V. Model: The annual electricity The annual heating saved SEC-Value Energyclass Climate zone Type of control consumption in kWh/m²/a (SEC) (AEC) in kWh in kWh Clock -34,08 4435 Average Central demand control -36,49...
Chapter 13 Declaration of conformity DECLARATION OF CONFORMITY Manufacturers: Brink Climate Systems B.V. Address: P.O. Box 11 NL-7950 AA Staphorst, The Netherlands Product : Renovent Sky 150 The product described above complies with following directives: 2006/95/EC (low voltage directive) 2004/108/EC (EMC directive)
Page 48
BRINK CLIMATE SYSTEMS B.V. P.O.Box 11 NL-7950 AA Staphorst The Netherlands Wethouder Wassebaliestraat 8 7951SN Staphorst The Netherlands T. +31 (0) 522 46 99 44 F. +31 (0) 522 46 94 00 info@brinkclimatesystems.nl www.brinkclimatesystems.nl...