3.2.6 RS-232 Speed Setting

The following programming sequence sets an optional slower RS-232 speed. This feature is available on Rev M boards or
higher and the Remote Account Manager Software, Version 6.4.i, must be used.
Factory setting = 1 (19200 baud rate)
8
5
1. Press
and enter your four-digit MASTER CODE
2. Enter
0
for 9600 baud rate or
3. Press
0
together to end this programming sequence (beeeeeep).
3.2.7 Switch Input Feature
The following programming sequence sets the switch input (main terminals #4 and #6) to either activate a relay(s) or call the
phone number programmed in directory code 0, 00, 000 or 0000. Refer to section 3.3.4 to determine which relay(s) will activate
when the switch input is activated. This feature is available on Rev K boards or higher.
Factory setting = 0 (switch input activates relay)
1
8
1. Press
and enter your four-digit MASTER CODE
The LCD display will read: KEY IN DIAL? 0=N 1=Y
1
2. Enter
for YES (the switch input will dial a phone number) or
press
(beep).
3. Press
0
together to end this programming sequence (beeeeeep).
3.2.8 Elevator Control Feature
This new elevator feature authorizes floor access to the Floor Level identified in the Resident Screen in the software program AND
to the floor(s) level identified in the Security Level screen. If this feature is turned off, access will be granted only the floor
identified in the user's security level. This feature is available on Rev K boards or higher.
Factory setting = 1 (new elevator function is turned ON)
7
5
1. Press
and enter your four-digit MASTER CODE
The LCD display will read: NEW EL FUNC? 0=N 1=Y
2. Enter
for YES (access is authorized to both the floor identified in the resident screen and to the floor(s) identified
1
in the user's security level) OR
screen), then press
3. Press
together to end this programming sequence (beeeeeep).
0
3.2.9 Single or Multiple Systems
This program sequence sets the telephone entry system to operate as a single unit on the phone line, or to share the phone line
with other units. If multiple systems are sharing the same phone line, then each one must be set as a "multiple system" and
each must have a unique master code.
Factory setting = Single System.
0
4
1. Press
and enter your four-digit MASTER CODE
2. Press
0
(beep) for a single system, OR
3. Press
together to end this programming sequence (beeeeeep).
0
28
1
for 19200 baud rate, then press
0
for NO (access is authorized only to the floor(s) identified in the security level
(beep).
1
?
?
?
?
(beep).
(beep).
?
?
?
?
(beep).
0
for NO (the switch input will activate the relay), then
?
?
?
?
(beep).
?
?
?
?
(beep).
(beep) for multiple systems.