2.3 Telephone Entry System Wiring

2.3.1 ALL Telephone Entry Systems - NO Tracker Expansion Boards
RS 232
1
2
3
4
5
6
3 2 1
CONTRAST
MIC
VOL
3 2 1
SPK
VOL
FEED
BACK
3 2 1
TONE ON
TONE OFF
HF
HS
RING
PHONE
CGND
PSW
Central Office
Phone Line Input
touch tone, loop start
"PHONE"
"PHONE"
Wiring MUST be twisted and
completely isolated from ground.
See section 2.1.4.
"CGND" Ground
See section 2.1.3.
"PSW" & "COM"
Switch Input -
See section 1.6 for Postal lock
connection.
A switch closure across these
terminals activates Relay 1 for its
programmed strike time.
See section 3.2.7 Switch Input
Feature.
Telephone Entry Systems:
Control up to 3 entry points with ONLY the system circuit board.
Note: Separate elevator control board required for elevator control.
Note: When more than 3 entry points are needed to be controlled,
expansion boards will be required to accomplish this, see next 2 pages.
Basic Gate Control Components
Card
Reader
18
BACKLITE
CUTOFF
8 LINE
DISPLAY
SINGLE
LINE
DISPLAY
ON
MASTER
Relay 0
CODE
OFF
KEYPAD
NO NC
C
Main Terminal
MIC
COM
SPKR
IMD
5VDC
IMC
Z
A
2C
2RY
UL 294
Tamper
Switch
(See Section 1.7).
To a Wiegand Input Aux. Terminal
500 ft max.
To #5 & #6 aux. terminal
for additional lighting on
card reader.
Gate Operator
To a Relay Input
Gate Operator
Normally Open
Elevator
Control
Terminal
ELEVATOR
1
2
3
Red
Black
White
Green
Red
Black
White
Green
16.5 VAC
16.5 VAC
Relay 2 Jumper
NO
NC
Power Input transformer for the phone system AND
1C
1NC
1NO
BAT
16AC
16AC
Power Input transformer for the Aux Terminal must
be connected for the system to operate.
20 VA
Power wire
polarity does
not matter.
40 VA
Red (Pos)
"BAT" & "COM" - 12 VDC Back-Up Battery Input (Phone System)
Black (Neg)
Back-up battery power for the phone system ONLY. A separate back-up battery is used for Wiegand devices
connected to the auxiliary terminal when back-up battery power is being used. See aux terminal #3 & #4.
"1NO" - Normally Open (NO)
"1NC" - Normally Closed (NC)
"1C" - Common (C)
"2RY" - Contact (NO or NC)
"2C" - Common (C)
NO - Normally Open
NC - Normally Closed
C - Common
Basic Door Control Components
Card Reader
To a
Wiegand
Input Aux.
Terminal
500 ft max.
To a
Relay Input
is wired to
Lock Power
(NO) relay
UL listed
input.
19
20 - DATA - 1
21 - DATA - 0
22 - COMMON
23
"Optional" Elevator Control
24
25
Board Required for Elevator
26
27
Control
28
(Left terminal on elevator control board)
29
Power for relays on elevator control board is NOT provided
30
by the system. Use separate UL listed power supply.
31
See Elevator Control Board Manual 2348-065.
32
33
34
35
Wiegand Input
36
26, 30 and 31-Bit Card Reader Input: Use 6 conductor,
#11 thru #14
stranded with overall shield. 18, 20, 22 or 24 gauge.
See section 2.1.2.
These terminals will activate
Relay 1 for its programmed
strike time.
Wiegand Input
#7 thru #10
26, 30 and 31-Bit Card Reader Input: Use 6 conductor,
These terminals will
stranded with overall shield. 18, 20, 22 or 24 gauge.
activate Relay 2 for its programmed
See section 2.1.2.
strike time.
#5 & #6 - 16 VAC Output: Can be used to power lights on
card readers that have additional lighting for outdoor use.
Black (Neg)
#3 & #4 - 12 VDC Back-Up Battery Input (Aux Term)
Red (Pos)
Back-up battery power for Wiegand inputs ONLY.
A separate back-up battery is needed for the phone system.
Power Input for Aux Terminal
20 VA
14-Pin aux terminal.
Powers RS-232, elevator control and Wiegand inputs.
Power wire
polarity does
not matter.
Receptacle Controlled By A Switch.
Power Input for Phone System
20 VA power for the 1835 phone system ONLY.
DO NOT use a 40 VA transformer for the 1835.
Power Input for 1837 Phone System
40 VA power for the 1837 phone system ONLY.
DO NOT use a 20 VA transformer for the 1837.
Relay 1 Input
Relay 2 Input
"2RY" Contact is set NO or NC with Relay 2 Jumper on board.
See section 4.6
Relay 0 Input
Door
Lock
Power for electric strike or magnetic
lock is NOT provided by the system.
Use separate UL listed power supply.
(Relay 1)
(Relay 2)
Do Not Connect Power To A
Power Transformers:
Use ONLY 16.5 VAC UL
Listed Transformer.
Run 18 AWG wire up to
100 Ft. Run 16 AWG wire
up to 200 Ft.
See section 2.1.1, 2.1.3
and 2.1.4 for further
information.
Relays activate a door lock
or a gate operator for their
programmed strike time at
a controlled access point.
Door Locks
Electric strike is wired
to Normally Open (NO)
relay input.
Magnetic lock is wired to
the Normally Closed (NC)
relay input.