2.3.3 Tracker Expansion Boards using Wireless Communication

The model 2358 Tracker Expansion Board (sold separately) allows you to expand the number of remote entry points that the telephone entry
system can control. One tracker expansion board is required for EACH remote entry point. Communicate wirelessly between the tracker
expansion boards and the 1830 Series controller without having to run wiring from each remote access point to the 1830 Series controller.
The model 1489 wireless tracker expansion board kit and the model 2361 wireless baseboard kit (each sold separately) plugged onto to circuit
boards for wireless communication. Wireless tracker expansion boards can be up to 100 ft from the telephone entry system (approximate).
This distance can be extended by using longer range antennas (sold separately) and/or a 2372 wireless dual band repeater (sold separately).
Each tracker expansion board must have a board address set on it to identify it to the telephone entry system. Board addresses 3-10 will
activate RELAY 2 and 11-18 will activate RELAY 1 on the telephone entry system. Board addresses can be set the same for multiple boards
(zone addresses) when MORE than 8 boards need to activate a specific RELAY (24 boards MAX for each relay). The tracker expansion boards
are pre-programmed with many features but can be programmed for specific needs when desired (See Tracker Expansion Board Manual
2358-065 for ALL programming options). See DoorKing's web site and the instruction sheets with the wireless kits for complete installation
information when using wireless communication.
This access control equipment must be installed inside of a controlled, protected or restricted area. See page 3 for more information.
Telephone Entry
System Circuit Board
8 LINE
DISPLAY
8
CH
RESET
PAIRED
8
NET
ON
ID
OFF
RCVD
SYNC LOST
SYNC REVD
DISPLAY
ALLOW
OFF/ON
DENY
HEARTBEAT
2361 Wireless
2361 Wireless
STATUS
2361 Wireless
Baseboard Kit
Baseboard Kit
Baseboard Kit
RF
STAT STRENGTH
ON
Relay 2 Jumper
MASTER
CODE
OFF
Set to NO
KEYPAD
Relay 0
NO
NO NC
C
Main Terminal
R
IMD
5VDC
IMC
Z
A
2C
2RY
1C
Relay 2
Relay 1
Relay 0
Main
Door/Gate
Relay 2 Connection Required.
IMPORTANT NOTE: ONLY use circuit
board 2361-010 Rev E or higher.
20
ELEVATOR
1
2
3
RF RANGE
DOORKING
2363-010
14
13
12
11
6
5
4
3
2
1
Auxiliary
4-Pin Terminal
DOORKING
Terminal
2361-010
Connection
NC
1NC
1NO
BAT
16AC
16AC
Wireless Dual Band Repeater
Antenna
Required
Antenna Note: This wireless system
works best when the antennas are in
direct-line-of-sight with each other, in
free air as high as possible above the
ground.
Wiegand Card
Power
Transformer
Required.
Connect to
#1 and #2.
overall shield.
Antenna Options
P/N 2372-080
Range is approximately
500 ft direct-line-of-sight.
Antenna
100 ft max
Required
Signal Note: Channel Number
and RF ID Number must match
on 2361 wireless baseboard kit
and ALL 1489 wireless kits.
Board
Address
Setting
RF
OUTPUT
SECURE
RF
RF
CODE
CODE
CODE
BOARD ADDRESS
DATA
STATUS
SENT
GOOD
BAD
ON
1
0
1
2
3
1489
1489
1489
4
Reader
5
6
#6 - #9
Wireless
Wireless
Wireless
7
Connect card
8
9
reader using
Kit
Kit
10
Kit
4 conductor,
RF RANGE
11
stranded with
RF ID
RF CH
12
PROGRAM
4
13
18, 20, 22 or
14
1489-010
24 gauge.
15
16
17
18
19
20
ENT
2358-010 Tracker
Expansion Board
At a Remote Entry Point
IMPORTANT NOTE: ONLY use circuit
board 2358-010 Rev L or higher.
Cabinet Mounted Longer Range Antenna
Externally Mounted
P/N 1514-002
Antenna Kit
P/N 1514-075
Range is approximately
200 ft direct-line-of-sight.
Range is approximately
500 ft direct-line-of-sight.
8
8
CH
NET
ID
Lock Power
UL listed
ALARM
AUX
2358-010
RELAY
RELAY
RELAY
NC
NC
NC
Door Lock
NO
NO
NO
#25 & #26
or Gate
21
Operator
22
23
24
25
26
27
28
RF
SYNC
29
RF
30
LOST
RF
31
Ground #32
STRENGTH
32
4
POWER
33
34
RESET
16 VAC
20 VA
Board Power
UL listed
#33 & #34
1835-067-A-9-18

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

1835

Table of Contents