Transmitter front display time and date are not correct

Symptoms
All or some of the below symptoms may be present.
Time and date is not correct on the Transmitter front display.
l
Red LED is flashing on the Transmitter front display.
l
Green LED may or may not be illuminated. When the green LED is illuminated, the Transmitter is currently broadcasting
l
(broadcast mode). When the green LED is NOT illuminated, the Transmitter is not broadcasting (standby mode).
GPS communication symbol
l
symbol
may not be displayed on the Transmitter front display.
NTP communication symbol
l
Problem
This may be due to the Transmitter switch position(s), bad or lacking information from the GPS Receiver or loss of NTP time
source.
Analyze
1. Verify the GPS communication symbol and parentheses are present or the NTP communication symbol is present.
2. From the switch panel on the back of the Transmitter, verify dip switch's #1 through # 8, which they may be in the wrong
position.
Switch
Function
1
NTP/GPS
2
LAN/Local
may not be displayed on the Transmitter front display. GPS communication parentheses
may not be displayed on the Transmitter front display.
Up Position
Receive time from NTP server.
LAN network connection is enabled.
Required for use of NTP time source.
Down Position
Receive time from a GPS Receiver.
Local USB and/or serial port
attached to unit is enabled.