Transmitter continues to power cycle and does not stay synced

Symptoms
All or some of the below symptoms may be present.
Transmitter front display screen is dim.
l
Transmitter syncs its time, cycles back to counting up, syncs its time, and then cycles again.
l
Cause
This may be due to a power issue.
Analyze
1. Verify power is present at the 120 VAC outlet.
2. Verify the power supply connection to the Transmitter and to the 120 VAC outlet is secure.
3. Using a multimeter, check for 9V at least 2.0A output from the power supply to the Transmitter.
4. If there is a UPS (surge protector/battery backup) in use, check the voltage carefully or bypass the UPS it to determine if it has
become defective.
Solution
1. If power to the Transmitter power supply is bad, resolve the issue.
2. If it's determine the UPS (surge protector/battery backup) is defective, replace UPS and bypass until it is replaced.
3. If power to the Transmitter power supply is good, replace the power supply as the first step.
4. If these steps do not resolve the problem, the Transmitter may be required to be replaced. For further assistance, contact
Primex Technical Support at 1-262-729-4860.